System Boiler 25kW 2020-present ErP A 82 fault codes

<p>The Evoke System 25 is a system boiler from Alpha, available at 25kW output. Produced 2020-present.</p>

Evoke System 25 Fault Codes 82

Code Description Severity Type
0A1 Ignition Failure (ProTec Plus) On Alpha ProTec Plus commercial boilers, 0A1 indicates ignition failure — gas supply or valve issue. Medium Engineer View Guide
0A5 Fan Speed Fault (ProTec Plus) On Alpha ProTec Plus boilers, 0A5 indicates a fan speed fault — flue or ventilation issue. High Engineer View Guide
1 Ignition Failure The boiler has failed to ignite. Possible causes include gas supply issues, defective ignition electrode, faulty… Medium DIY View Guide
12 Cylinder Sensor Fault (FlowSmart) The cylinder temperature sensor has a wiring fault or has failed. Relevant on FlowSmart system boilers… Medium Engineer View Guide
15 Internal Wiring Error An incorrect wiring configuration has been detected internally. Usually only occurs after maintenance or installation work. High Engineer View Guide
16 Fan Fault The fan has a fault — either a wiring connection issue, a failed fan motor, or… High Engineer View Guide
2 Overheat Boiler Lockout The boiler has overheated and locked out. Caused by pump or flow problems, blocked heat exchanger,… High Engineer View Guide
20 Flame Sensing Fault The flame sensing electrode is not detecting the flame correctly, or there is a PCB fault… Medium Engineer View Guide
24 Control Panel Button Fault A control panel button is stuck in the ON position, or there is a fault with… Medium Engineer View Guide
25 Overheat Lockout (Secondary) A secondary overheat lockout triggered by air in the heat exchanger, blocked flow, flue restriction, or… High Engineer View Guide
27 Insufficient Primary Flow The boiler is not detecting adequate water flow through the primary circuit. Caused by blockage, restricted… Medium Engineer View Guide
29 Flue Sensor Fault The flue gas temperature sensor has a wiring fault or has failed. Medium Engineer View Guide
3 High Flue Temperature The flue gas temperature has reached a dangerous level. Usually caused by a blocked or restricted… High Engineer View Guide
31 Loss of Communication with External Control The boiler has lost communication with the Alpha Climatic remote control system. Low Engineer View Guide
37 Low Supply Voltage The mains power supply voltage has dropped below the minimum operating level for the boiler. Medium Engineer View Guide
38 Loss of Flame Rectification (Type 1) The boiler's flame rectification circuit has detected a fault with the flame — the electrode may… Medium Engineer View Guide
4 Gas Valve Electrical Connection Fault There is an electrical connection fault at the gas valve — either the valve lead connection… High Engineer View Guide
43 Loss of Flame Rectification (Type 2) Persistent flame rectification loss — similar to code 38 but indicating a more established problem with… Medium Engineer View Guide
44 Safety Lockout — External Control Cycling The boiler has locked out due to too many rapid on/off requests from an external control… Medium DIY View Guide
46 External Sensor Fault The optional external temperature sensor (for weather compensation) has a wiring fault or has failed. Low Engineer View Guide
47 Reduced Burner Output — Flue Thermostat Active The flue thermostat has sensed high flue gas temperature and reduced the burner output as protection.… Medium Engineer View Guide
49 Return Sensor High Temperature The return sensor has detected an unusually high temperature on the heat exchanger return circuit, indicating… Medium Engineer View Guide
5 Heating Flow Sensor Fault The central heating flow temperature sensor has a wiring fault or the sensor itself has failed. Medium Engineer View Guide
51 Climatic RF Communication Fault The wireless communication between the boiler and the Alpha Climatic remote control transmitter has failed. Could… Low DIY View Guide
6 DHW Sensor Fault The domestic hot water temperature sensor has a wiring fault or has failed. Relevant on combi… Medium Engineer View Guide
60 Pump Error (E-Tec / Evoke) On Alpha E-Tec and Evoke combi boilers, code 60 indicates the pump is stuck or has… High Engineer View Guide
61 Air in Pump / Restricted CH Flow (E-Tec / Evoke) On Alpha E-Tec and Evoke boilers, code 61 indicates air in the circulation pump or restricted… Medium DIY View Guide
70 Return/Flow Sensor Wiring Fault (E-Tec) On Alpha E-Tec boilers, code 70 indicates a wiring or connection issue with the return or… Medium Engineer View Guide
71 No Primary Temperature Rise Detected (E-Tec Regular) After ignition, the boiler has not detected a temperature rise in the primary circuit — indicating… High Engineer View Guide
8 Maximum Number of Resets Exceeded The boiler has reached its maximum reset count. Refer to the fault history codes to identify… High Engineer View Guide
E01 Ignition Failure The boiler has failed to ignite — the burner attempted to light but no flame was… Medium DIY View Guide
E02 Flame Supervision Fault The flame supervision device has detected a problem. High Engineer View Guide
E03 Overheat Protection Activated The boiler exceeded maximum temperature. High Engineer View Guide
E04 High Limit Thermostat Tripped The high-limit (STB) safety thermostat has activated due to excessive temperature, cutting the gas supply. High Engineer View Guide
E05 Return Sensor Fault The return temperature sensor (NTC thermistor) has failed or has a wiring fault. Medium Engineer View Guide
E06 Flue Sensor Fault The flue gas temperature sensor is giving an out-of-range reading. Medium Engineer View Guide
E07 Overheat Sensor Tripped The main overheat safety sensor (STB) has activated due to excessive boiler temperature. High Engineer View Guide
E08 Flue Overheat Sensor Tripped The flue temperature sensor has detected dangerously high exhaust temperatures. High Engineer View Guide
E09 Fan Fault — No Air Pressure The fan has not generated sufficient air pressure for the air pressure switch to confirm safe… High Engineer View Guide
E10 Low Water Pressure The system water pressure has dropped below 0.6 bar — the minimum required for an Alpha… Low DIY View Guide
E11 Return Temperature Too High The return temperature from the heating circuit is higher than expected, indicating possible circulation issues. Medium Engineer View Guide
E12 DHW NTC Sensor Fault The hot water NTC sensor is faulty. Medium Engineer View Guide
E13 Outdoor Sensor Fault The outdoor temperature sensor is faulty. Low Engineer View Guide
E14 Pressure Sensor Fault The electronic water pressure sensor is faulty. Medium Engineer View Guide
E15 Low Gas Pressure The gas supply pressure at the boiler is below the minimum operating threshold. High Engineer View Guide
E16 Maximum Temperature Exceeded The boiler water temperature has exceeded its absolute maximum limit. High Engineer View Guide
E17 Gas Valve Fault The gas valve is not responding. High Engineer View Guide
E18 PCB Communication Error Internal PCB communication has failed. High Engineer View Guide
E19 Fan Fault The fan is not running correctly. High Engineer View Guide
E20 Flame Failure / No Flame Detected The boiler cannot detect a flame. The burner has failed to light or the ionisation electrode… Medium Engineer View Guide
E21 Condensate Blocked The condensate drain is blocked or frozen. Medium DIY View Guide
E22 Flame Lost During Operation The flame was lost during running. High Engineer View Guide
E23 Low Gas Pressure Gas supply pressure is too low. High Engineer View Guide
E24 Air Pressure Switch Fault The APS is not detecting airflow. High Engineer View Guide
E25 Dry Fire / Low Water Detected The boiler has attempted to fire without detecting sufficient water flow, indicating very low water pressure… High Engineer View Guide
E26 Diverter Valve Fault The diverter valve is stuck. Medium Engineer View Guide
E27 Rapid Temperature Rise Flow temperature rising too quickly. High Engineer View Guide
E28 Flue Fault There is a problem with the flue — it may be blocked, incorrectly installed, or the… High Engineer View Guide
E29 Flow/Return Differential Fault Temperature gap between flow and return is abnormal. Medium Engineer View Guide
E30 Diverter Valve Fault The diverter valve (which switches flow between heating and hot water on a combi boiler) is… Medium Engineer View Guide
E31 Pump Fault The pump is not running. High Engineer View Guide
E32 EEPROM Error PCB memory error. High Engineer View Guide
E33 PCB Internal Fault The PCB has detected an internal fault. High Engineer View Guide
E34 Overheat Lockout The boiler has reached an unsafe temperature and the overheat thermostat has triggered a lockout. High Engineer View Guide
E35 Frost Protection Active Frost protection is running. Medium DIY View Guide
E36 Flue Gas Overheat The flue gas temperature is too high. High Engineer View Guide
E37 eBUS Fault Communication bus error. Medium Engineer View Guide
E38 Mains Voltage Fault Mains voltage outside range. Medium Engineer View Guide
E39 Return NTC Short Circuit Return sensor wiring has shorted. Medium Engineer View Guide
E40 False Flame Detected An ionisation signal has been detected when no flame should be present. High Engineer View Guide
E41 Flow NTC Short Circuit Flow sensor wiring has shorted. Medium Engineer View Guide
E42 DHW NTC Short Circuit DHW sensor wiring has shorted. Medium Engineer View Guide
E43 Combustion Quality Fault Air/gas mixture outside limits. High Engineer View Guide
E44 Flame Detected After Shutdown Flame signal present with gas valve closed. High Engineer View Guide
E45 Coding Plug Fault Coding plug missing or unreadable. High Engineer View Guide
E50 DHW Sensor Fault The domestic hot water temperature sensor is giving an incorrect reading or has failed. Medium Engineer View Guide
E55 Flow Temperature Overheat The flow temperature is excessively high, causing a protective lockout. High Engineer View Guide
E60 Fan Fault The fan is not operating at the required speed or has stopped working. High Engineer View Guide
E70 Chip Card / Configuration Error The boiler's configuration chip card is not reading correctly or has not been properly installed. Medium Engineer View Guide
E90 Pressure Switch Fault The air pressure switch is not registering correctly — this switch confirms that the fan is… High Engineer View Guide
E96 Gas Valve Fault The gas valve has an electronic fault and is not operating correctly. High Engineer View Guide
SR Service Reminder (E-Tec) Not a fault — this is a service reminder on Alpha E-Tec boilers, indicating the service… Low DIY View Guide