Baxi 600 System 2 18kW

System Boiler 18kW 2018-present ErP A 84 fault codes

<p>The Baxi 600 System 2 18kW is a system boiler from Baxi, available at 18kW output. Produced 2018-present.</p>

Baxi 600 System 2 18kW Fault Codes 84

Code Description Severity Type
111 Maximum Flow Temperature Limit Reached (EcoBlue) On Baxi EcoBlue boilers, code 111 indicates the maximum flow temperature limit has been reached —… Medium Engineer View Guide
117 Water Pressure Too High System water pressure has exceeded the safe maximum — likely above 2.9 bar. Do NOT add… Medium Engineer View Guide
118 Water Pressure Too Low (EcoBlue) On Baxi EcoBlue boilers, code 118 indicates system water pressure is too low (below 0.5 bar). Low DIY View Guide
127 Legionella Protection Temperature Not Reached The boiler attempted a legionella prevention cycle (periodic high-temperature DHW heating) but could not reach the… Low Engineer View Guide
162 Air Pressure Switch Fault (EcoBlue) On Baxi EcoBlue boilers, code 162 indicates the air pressure switch has a fault — it… High Engineer View Guide
166 Air Pressure Switch Fault (Secondary) A secondary air pressure switch fault on Baxi EcoBlue boilers. High Engineer View Guide
2 RED FLASHES Boiler Overheat Tripped (EcoBlue/MainEco) On Baxi EcoBlue and MainEco boilers, 2 red flashes indicates the overheat thermostat has tripped. High Engineer View Guide
270 Dry Fire / No Water Circulation The boiler has detected firing without adequate water circulation — a 'dry fire' condition. The pump… High Engineer View Guide
3 GREEN FLASHES Temporary Flame Loss (EcoBlue/MainEco) On Baxi EcoBlue and MainEco boilers, 3 green flashes indicates a temporary flame loss. The boiler… Low DIY View Guide
3 RED FLASHES Ignition Failure — 5 Attempts (EcoBlue/MainEco) On Baxi EcoBlue and MainEco boilers, 3 red flashes means the boiler has failed to ignite… Medium DIY View Guide
4 RED FLASHES Fan Fault (EcoBlue/MainEco) On Baxi EcoBlue and MainEco boilers, 4 red flashes indicates a fan fault. High Engineer View Guide
432 Earth Connector Error (EcoBlue) The boiler has detected an issue with the earth connection in the electrical supply. High Engineer View Guide
433 Heat Exchanger Overtemperature (EcoBlue) The heat exchanger temperature has exceeded 95°C. This is a more severe overheat condition than the… High Engineer View Guide
E.01-.04 Flame Lost 5 Times in 24 Hours (200/400) On Baxi 200/400 boilers, E.01-.04 indicates flame has been lost 5 times within 24 hours while… High Engineer View Guide
E.02-.07 No/Low System Water Pressure (200/400) On Baxi 200/400 boilers, E.02-.07 indicates system pressure is below 0.5 bar. Low DIY View Guide
E.04-.10 Failure to Light (200/400) On Baxi 200/400 boilers, E.04-.10 indicates the boiler has failed to ignite — possibly a gas… Medium DIY View Guide
E.04-.12 False Flame Signal (200/400) On Baxi 200/400 boilers, E.04-.12 indicates a false flame signal is present — ionisation detected without… High Engineer View Guide
E0 Temperature Sensor Fault (Avanta) On Baxi Avanta boilers, E0 indicates a temperature sensor fault. Medium Engineer View Guide
E1 Overheat (Avanta) On Baxi Avanta boilers, E1 indicates the boiler has overheated. Try bleeding radiators first. High Engineer View Guide
E10 Flow NTC Sensor Fault The flow temperature sensor is giving an incorrect reading or has failed. Medium Engineer View Guide
E109 Pre-Heating Circuit Fault A fault has been detected in the pre-heating circuit. This affects the boiler's ability to provide… Medium Engineer View Guide
E11 Return NTC Sensor Fault The return temperature sensor is giving an incorrect reading or has failed. Medium Engineer View Guide
E110 Boiler Overheat The boiler has reached its maximum safe operating temperature and the safety thermostat has locked it… High Engineer View Guide
E113 Condensate Trap/System Blocked The condensate drainage system is blocked. This can occur when the condensate siphon is full after… Medium DIY View Guide
E116 Flow Temperature Too High The boiler flow temperature has exceeded its maximum safe level, triggering a high-temperature lockout. High Engineer View Guide
E117 Gas Valve Error The gas valve has detected a fault — it may not be opening, closing, or responding… High Engineer View Guide
E118 Flame Without Demand The boiler is detecting a flame signal when no heat demand exists — a safety-critical condition. High Engineer View Guide
E119 Low Water Pressure The most common Baxi fault code. System water pressure has dropped below 0.5 bar — the… Low DIY View Guide
E12 DHW Sensor Fault The domestic hot water temperature sensor has a fault. Relevant on combi boilers. Medium Engineer View Guide
E125 Circulation Fault (Primary) Water is not circulating properly through the primary heating circuit. Usually caused by a faulty pump,… Medium Engineer View Guide
E128 Frequent Flame Failure The boiler has lost its flame 12 times in succession, triggering a safety lockout. High Engineer View Guide
E130 Overheat Thermostat Activated The boiler's safety overheat thermostat has been triggered. The boiler has exceeded its safe operating temperature. High Engineer View Guide
E131 Flue Overheat Lockout The flue temperature has reached an unsafe level, triggering the flue thermostat. High Engineer View Guide
E133 Ignition Failure / Frozen Condensate The boiler has failed to ignite or there is a gas supply fault. In winter, this… Medium DIY View Guide
E134 Gas Valve Relay Error The gas valve relay has failed or is not responding correctly. The boiler cannot safely control… High Engineer View Guide
E135 Airflow Fault / Air Pressure Switch The air pressure switch is not registering correctly, preventing safe ignition. High Engineer View Guide
E14 Flow NTC Open Circuit The flow temperature sensor circuit is broken. Medium Engineer View Guide
E15 Fan Fault The fan is not running at the correct speed or has stopped. High Engineer View Guide
E151 PCB Internal Fault The Printed Circuit Board has detected an internal fault that cannot be reset by the user. High Engineer View Guide
E154 Circulation Pump Fault The central heating pump is not running or is not producing sufficient water flow. The boiler… High Engineer View Guide
E16 Air Pressure Switch Open The APS is not closing when the fan runs. High Engineer View Guide
E160 Fan Fault The boiler fan is not operating correctly — it may not be running, running too slowly,… High Engineer View Guide
E161 Fan Fault (Secondary) A secondary fan fault — the fan speed sensor or air pressure switch is giving an… High Engineer View Guide
E164 Pressure Sensor Fault The water pressure sensor is giving an incorrect or out-of-range reading. Medium Engineer View Guide
E167 PCB Error The Printed Circuit Board has a detected fault (non-lockout version). Medium Engineer View Guide
E168 PCB Fault / Lockout The main Printed Circuit Board has detected an unspecified fault and locked the boiler out. This… High Engineer View Guide
E169 Ignition Lockout (After 5 Attempts) The boiler has failed to ignite after 5 attempts and locked out. Medium DIY View Guide
E17 Return NTC Open Circuit The return temperature sensor circuit is broken. Medium Engineer View Guide
E18 DHW NTC Open Circuit The hot water sensor circuit is broken. Medium Engineer View Guide
E180 Water Hammer / Circulation Noise Noise from water circulation — kettling, banging or hammering sounds — indicating scale buildup on the… Medium Engineer View Guide
E19 Flow NTC Short Circuit The flow NTC wiring has a short circuit. Medium Engineer View Guide
E193 Return Temperature Sensor Fault The return water temperature sensor has a fault in its wiring or has failed. Medium Engineer View Guide
E2 Poor Circulation (Avanta) On Baxi Avanta boilers, E2 indicates poor or no water circulation through the system. Medium DIY View Guide
E20 Flame Failure — Lockout The boiler failed to detect a flame after the ignition sequence, or the flame extinguished during… Medium DIY View Guide
E21 Condensate Blocked The condensate drain is blocked or frozen. Medium DIY View Guide
E215 Fan Overspeed The boiler fan is running above its maximum rated speed. Indicates a fault with the fan… High Engineer View Guide
E22 PCB EEPROM Fault The PCB's internal memory has an error. High Engineer View Guide
E220 Gas Valve Failure to Open The gas valve has received the command to open but has not done so — preventing… High Engineer View Guide
E23 Diverter Valve Fault The diverter valve is stuck or not switching between heating and hot water. Medium Engineer View Guide
E24 Flame Lost During Operation The flame was detected but lost during running. High Engineer View Guide
E25 Rapid Temperature Rise Flow temperature rising faster than safe limits. High Engineer View Guide
E26 Gas Valve Relay Fault The PCB relay for the gas valve has failed. High Engineer View Guide
E27 Pressure Sensor Fault The electronic water pressure sensor is faulty. Medium Engineer View Guide
E28 Frozen Condensate / Flame Failure (Winter) Baxi specifically flags E28 as associated with frozen condensate pipes in winter, making it distinct from… Medium DIY View Guide
E29 Outdoor Sensor Fault The outdoor temperature sensor is disconnected or faulty. Low Engineer View Guide
E3 PCB Fault (Avanta) On Baxi Avanta boilers, E3 indicates a Printed Circuit Board fault. High Engineer View Guide
E30 eBUS Communication Fault The eBUS communication line has a fault. Medium Engineer View Guide
E31 Frost Protection Active The boiler is running frost protection cycles to prevent freezing. Medium DIY View Guide
E32 Flame Detected After Shutdown A flame signal is present when the gas valve should be closed. High Engineer View Guide
E33 Combustion Quality Fault The air/gas mixture is outside the permitted range. High Engineer View Guide
E34 Mains Voltage Fault The mains supply voltage is outside acceptable range. Medium Engineer View Guide
E35 Phase/Neutral Reversed The electrical supply polarity is reversed. High Engineer View Guide
E4 Ignition Failure (Avanta) On Baxi Avanta boilers, E4 indicates ignition failure. Medium DIY View Guide
E40 Return Temperature Sensor Fault The return water temperature NTC sensor has developed a fault. It may have an open circuit… Medium Engineer View Guide
E50 Flow Temperature Sensor Fault The flow water temperature NTC sensor has developed a fault. The boiler cannot accurately measure the… Medium Engineer View Guide
E501 eBUS/Communication Fault A communication fault between the boiler and a connected external controller (thermostat, zone control, etc.) over… Medium Engineer View Guide
E53 Condensate Pipe Frozen / Blocked Baxi's explicit condensate blockage code. Shown when the internal condensate system detects a backup caused by… Medium DIY View Guide
E55 Fan Speed Fault The fan is running outside its normal speed range — either too fast or too slow.… High Engineer View Guide
E78 Water Pressure Sensor Fault The electronic water pressure sensor is giving an incorrect reading. The boiler cannot verify the system… Medium Engineer View Guide
E83 Flow/Return Differential Error The temperature difference between the flow and return is outside the expected range. This usually indicates… Medium Engineer View Guide
E84 Flow/Return Sensor Implausible The flow and return temperature sensors are giving readings that are logically impossible, such as the… Medium Engineer View Guide
E92 Combustion Error The combustion quality is outside the permitted range. The air/gas mixture is not correct for safe… High Engineer View Guide
H.01-.05 Flow/Return Temperature Difference Too High (200/400) On Baxi 200 and 400 series boilers, code H.01-.05 indicates the temperature difference between flow and… Medium Engineer View Guide
H.01-.08 Flow Temperature Rising Too Fast (200/400) On Baxi 200/400 boilers, H.01-.08 indicates the flow temperature is increasing too quickly — insufficient circulation… Medium Engineer View Guide