Worcester Bosch

Greenstar 8000 Life 50kW

Combi Boiler 50kW 2019-present ErP A 80 fault codes

<p>The Greenstar 8000 Life 50kW is a combi boiler from Worcester Bosch, available at 50kW output. Produced 2019-present.</p>

Greenstar 8000 Life 50kW Fault Codes 80

Code Description Severity Type
1017 W Low Water Pressure Warning (8000 Series) On Worcester Greenstar 8000 boilers, code 1017 W indicates the system water pressure is too low.… Low DIY View Guide
1065 B Pressure Sensor Defective (8000 Series) On 8000 Series boilers, code 1065 B indicates the pressure sensor is not connected or has… Medium Engineer View Guide
1073 W Flow Temperature Sensor Short Circuit (8000 Series) On 8000 Series boilers, code 1073 W indicates a short circuit in the flow temperature sensor. Medium Engineer View Guide
1074 W Flow Temperature Sensor No Signal (8000 Series) On 8000 Series boilers, code 1074 W means the flow temperature sensor is not providing a… Medium Engineer View Guide
224 V Safety Temperature Limiter Tripped (8000 Series) On 8000 Series boilers, code 224 V means the safety temperature limiter has operated. 'V' indicates… High Engineer View Guide
227 Ignition Lockout (Older CDi Models) On older Worcester Greenstar CDi models, fault code 227 indicates ignition failure after multiple attempts. Medium DIY View Guide
227 V No Flame Signal (8000 Series Lockout) On 8000 Series boilers, code 227 V is a lockout (V = lockout) for no flame… Medium DIY View Guide
2927 B Flame Lost During Operation (8000 Series) On 8000 Series boilers, code 2927 B means the ionisation current was insufficient during the burning… Medium DIY View Guide
2948 B No Flame Signal (8000 Series) On Greenstar 8000 boilers, code 2948 B indicates no flame signal was detected. At low output… Medium Engineer View Guide
2948 V Flue Gas Sensor Open Circuit The flue gas NTC circuit is broken. Medium Engineer View Guide
2965 B Flow Temperature Too High (8000 Series) On 8000 Series boilers, code 2965 B means the flow temperature has exceeded safe limits. High Engineer View Guide
2965 V Flue Gas Sensor Short Circuit The flue gas NTC has a short circuit. Medium Engineer View Guide
2970 B System Pressure Drop Too Rapid (8000 Series) On 8000 Series boilers, code 2970 B means system pressure is dropping at an unusually rapid… High Engineer View Guide
2971 B System Pressure Too Low (8000 Series) On 8000 Series boilers, code 2971 B indicates system pressure is below the minimum. The boiler… Low DIY View Guide
360 V Incompatible Code Plug (8000 Series) On 8000 Series boilers, code 360 V means the code plug (boiler identification module) is not… Medium Engineer View Guide
6A Safety Fuse Fault The internal safety fuse has blown. This can be caused by tampering, poor maintenance, or loose… High Engineer View Guide
9U Blocked Condensate / Condense Sensor The condensate system is blocked or the condensate sensor is indicating a problem. Most commonly caused… Medium DIY View Guide
9U 257 Appliance Variant Not Set The boiler variant has not been correctly configured. High Engineer View Guide
A1 Pump Stuck or Running Dry The circulation pump is not running correctly — either it is seized, running without water, or… High Engineer View Guide
A21 Thermostat / Receiver Communication Fault The boiler cannot communicate with the wireless thermostat receiver. Usually caused by low batteries in the… Low DIY View Guide
A21 281 Pump Blockage / Circulation Fault The pump is blocked, preventing proper water circulation through the system. High Engineer View Guide
A22 Loss of RF Signal The boiler has lost the wireless radio frequency signal from the room thermostat. The thermostat may… Low DIY View Guide
A281 Internal Water Leak Detected The boiler has detected an internal water leak. Water may be dripping onto internal components which… High Engineer View Guide
A61 Gas Valve Fault There is a fault with the gas valve — it may not be opening or closing… High Engineer View Guide
A7 Flow Temperature Sensor Fault The flow NTC thermistor is giving a reading outside its expected range. Similar to E2, typically… Medium Engineer View Guide
A7 246 Diverter Valve Fault The diverter valve is not switching correctly between heating and hot water. Medium Engineer View Guide
A8 Return Temperature Sensor Fault The return NTC thermistor is giving an out-of-range reading. Medium Engineer View Guide
A8 246 DHW Thermistor Fault The domestic hot water NTC sensor has a fault. Medium Engineer View Guide
B1 PCB Internal Fault The main Printed Circuit Board has detected an internal error it cannot recover from. High Engineer View Guide
B1 257 Coding Plug Missing The boiler's coding plug is not detected. High Engineer View Guide
B7 Gas Valve Short Circuit A short circuit has been detected in the gas valve wiring or the valve itself. High Engineer View Guide
B7 257 Internal Communication Error There is an internal communication error between boiler components, typically involving the printed circuit board (PCB). High Engineer View Guide
C1 Fan Fault / Air Pressure Switch Fault The fan is not running at the correct speed or the air pressure switch is not… High Engineer View Guide
C1 221 Flow Sensor Short Circuit The flow NTC sensor wiring has a short circuit. Medium Engineer View Guide
C1 238 Return Sensor Short Circuit The return NTC sensor wiring has a short circuit. Medium Engineer View Guide
C4 Flue Temperature Sensor Fault The flue gas temperature sensor is giving an out-of-range or implausible reading. Medium Engineer View Guide
C4 218 Air Pressure Switch Stuck Closed The APS is stuck in the closed position. High Engineer View Guide
C6 Fan Speed Error The boiler fan is not running at the correct speed. This prevents safe ignition as the… High Engineer View Guide
C7 Fan Overspeed Error The boiler fan is running faster than its rated speed, which can indicate a fault with… High Engineer View Guide
CE 201 Flow Temperature Sensor Fault The flow temperature sensor (NTC thermistor) has a fault in its wiring or the sensor itself… Medium Engineer View Guide
CE 203 Flow Sensor Fault The flow temperature sensor is giving an implausible or out-of-range reading. Medium Engineer View Guide
CE 207 Low Water Pressure The boiler's water pressure has dropped below the safe minimum level. One of the easiest faults… Low DIY View Guide
CE 210 Primary Flow Sensor Fault The primary flow NTC sensor is giving an out-of-range reading on modern Greenstar models. Medium Engineer View Guide
D1 200 Heating System Circulation Fault The boiler is detecting poor water circulation in the heating system. The temperature difference between flow… Medium Engineer View Guide
D1 204 Boiler Identification Module Fault The boiler's identification module (SCB) is not communicating correctly with the main PCB. Usually occurs after… Medium Engineer View Guide
D1 218 Flow/Return Temp Difference Too High Poor circulation — the temperature gap between flow and return is abnormally large. Medium Engineer View Guide
D3 External Thermostat Short Circuit The external thermostat or room controller wiring has a short circuit. The boiler cannot receive a… Medium Engineer View Guide
D3 218 External Thermostat Circuit Fault The wiring from the room thermostat has a fault. Medium Engineer View Guide
D4 System Purge Required / Air in System Air has been detected in the primary circuit after a period of non-use or maintenance work.… Low DIY View Guide
D5 Primary Flow Thermistor Fault The main flow temperature sensor is giving an out-of-range reading, preventing the boiler from monitoring water… Medium Engineer View Guide
E2 Flow NTC Sensor Fault The flow temperature sensor (NTC thermistor) is giving an incorrect reading — either out of range… Medium Engineer View Guide
E2 218 Flow Temperature Sensor Fault The flow temperature NTC sensor has developed a fault. It may be reading incorrectly or have… Medium Engineer View Guide
E5 Flow Temperature Too High The boiler flow temperature has exceeded 105°C — the maximum safe limit. A serious overheat condition. High Engineer View Guide
E5 218 Flow Sensor Open Circuit The flow NTC circuit is broken. Medium Engineer View Guide
E5 238 Return Sensor Open Circuit The return NTC circuit is broken. Medium Engineer View Guide
E9 Overheat Fault The boiler's safety thermostat has detected dangerously high temperatures and triggered a lockout. Usually caused by… High Engineer View Guide
E9 219 Safety Sensor Fault — Temperature Exceeded The safety temperature sensor has detected a temperature in excess of 105°C, or the sensor contacts… High Engineer View Guide
E9 224 Overheat — Safety Limiter Tripped (Code 224) The safety temperature limiter has tripped due to overheating. Sub-code 224 typically indicates this occurred during… High Engineer View Guide
E9 277 Safety Sensor High Temperature (GB162) On Worcester GB162 commercial boilers, code E9 277 means the safety temperature sensor has measured a… High Engineer View Guide
EA 227 Ignition Failure / No Flame Detected The boiler has failed to detect a flame after four ignition attempts, triggering a safety lockout.… Medium DIY View Guide
EA 229 Flame Loss During Operation The boiler ignited successfully but then lost the flame during operation. Very common in winter due… Medium DIY View Guide
EA 234 Flame Not Detected After Start The boiler attempted to start but could not detect a flame. Similar to EA 227, this… Medium DIY View Guide
EA 261 Heat Control Module (HCM) Potentially Defective On Greenstar i boilers, EA 261 indicates the Heat Control Module (HCM) may be defective. The… Medium DIY View Guide
EA 306 Flame Lost After 10 Seconds Flame established but lost within 10 seconds. High Engineer View Guide
EA 338 Flame Detected When Not Expected The boiler has detected a flame signal when the gas valve should be closed. This is… High Engineer View Guide
EF Maximum Reset Count Exceeded The boiler has been reset too many times without the underlying fault being resolved, and has… High Engineer View Guide
EF 349 Central Heating Boil Detected The boiler is operating at minimum burner load but the temperature difference between flow and return… High Engineer View Guide
F0 Internal Component Fault A general internal fault code indicating a component has failed. The specific sub-code (e.g. F0 238)… High Engineer View Guide
F7 Flame Detected After Shutdown (Unsafe) The boiler's ionisation circuit is detecting a flame signal when the gas valve should be closed.… High Engineer View Guide
FA Flue Condensate Blocked / Siphon Full The condensate siphon inside the boiler is full or blocked, preventing the boiler from starting. Common… Medium DIY View Guide
FA 306 False Flame — Ionisation After Burner Stop The boiler has detected ionisation current (flame signal) after the burner has been commanded to stop.… High Engineer View Guide
FD Temperature/Pressure Sensor Combination Fault Multiple sensor faults have been detected simultaneously, or the temperature/pressure combination is outside safe operating parameters. High Engineer View Guide
FD 231 Mains Power Interrupted During Lockout The mains power supply was interrupted while the boiler was in a lockout state. This code… Low DIY View Guide
H02 Central Heating Sensor Fault The central heating temperature sensor is giving an incorrect reading. Medium Engineer View Guide
H02 218 Status: Heating Demand The boiler is running to satisfy a central heating demand. Normal operation. Medium DIY View Guide
H06 Gas Valve Fault The gas valve is not operating correctly according to the boiler control system. High Engineer View Guide
H06 218 Status: DHW Demand The boiler is running to provide hot water. Normal operation. Medium DIY View Guide
H07 Low Water Pressure Warning A low pressure warning code displayed on some Worcester Greenstar models. The boiler may continue to… Low DIY View Guide
H07 218 Status: Standby The boiler is in standby with no active demand. Medium DIY View Guide
HRE Boiler Resetting Frequently The boiler has been resetting itself repeatedly. This indicates a recurring fault that the boiler is… Medium Engineer View Guide