Combi Boiler 24kW 2010-2016 ErP A 46 fault codes

<p>The Genus HE 24 is a combi boiler from Ariston, available at 24kW output. Produced 2010-2016.</p>

Genus HE 24 Fault Codes 46

Code Description Severity Type
101 Overheat — Safety Thermostat Triggered The boiler has overheated and the safety thermostat has shut it down. Usually caused by poor… High Engineer View Guide
102 Pressure Sensor Error (E-Combi Evo) On Ariston E-Combi Evo boilers, code 102 indicates a pressure sensor fault. Medium Engineer View Guide
103 Insufficient Water Circulation The boiler is not detecting adequate water circulation through the primary heating circuit. Usually caused by… Medium Engineer View Guide
104 Insufficient Circulation / Pump Fault The pump is not providing adequate water circulation. The temperature rise is too fast, indicating restricted… High Engineer View Guide
105 Insufficient Circulation on DHW Circuit The domestic hot water circuit has poor circulation. The flow rate through the plate heat exchanger… Medium Engineer View Guide
106 Low Water Pressure System water pressure has dropped below the safe operating level. The boiler cannot operate without adequate… Low DIY View Guide
107 Low Water Pressure with No Reset System pressure is critically low and the boiler has locked out. Unlike code 106, this will… Medium DIY View Guide
108 Insufficient Water — Refill Required On Ariston combi boilers, code 108 indicates the system has insufficient water and needs to be… Low DIY View Guide
109 System Pressure Too High (Clas Net One) On Ariston Clas Net One boilers, code 109 indicates system pressure has exceeded 3 bar. Medium Engineer View Guide
110 CH Flow Temperature Sensor Fault The central heating flow temperature sensor (probe) has an open circuit or short circuit fault. Medium Engineer View Guide
111 Pump Fault The circulation pump is not running or has seized. High Engineer View Guide
112 CH Return Temperature Sensor Fault The central heating return temperature sensor has an open circuit or short circuit fault. Medium Engineer View Guide
114 Diverter Valve Fault The diverter valve is not switching correctly. Medium Engineer View Guide
115 Condensate Blocked The condensate drain is blocked or frozen. Medium DIY View Guide
116 PCB Communication Error Internal PCB data communication has failed. High Engineer View Guide
117 eBUS Fault The eBUS communication line has a fault. Medium Engineer View Guide
118 Flame Detected After Shutdown Flame signal present when gas valve should be closed. High Engineer View Guide
119 Combustion Quality Fault Air/gas mixture outside limits. High Engineer View Guide
120 Flow/Return Sensors Reversed The sensors are fitted to the wrong pipes. Medium Engineer View Guide
121 Mains Voltage Fault Mains voltage outside acceptable range. Medium Engineer View Guide
122 Phase/Neutral Reversed Electrical polarity is reversed. High Engineer View Guide
123 Frost Protection Active Frost protection cycles running. Medium DIY View Guide
124 EEPROM Error PCB memory error. High Engineer View Guide
125 Coding Plug Fault Boiler coding plug unreadable. High Engineer View Guide
126 Outdoor Sensor Fault Outdoor sensor faulty or disconnected. Low Engineer View Guide
127 Fan Speed Error Fan running outside expected range. High Engineer View Guide
128 Gas Valve Relay Fault PCB gas valve relay has failed. High Engineer View Guide
201 Flow Temperature Sensor Fault The flow NTC temperature sensor has an open circuit or short circuit. The boiler cannot monitor… Medium Engineer View Guide
202 DHW Temperature Sensor Fault The domestic hot water NTC temperature sensor has developed a fault. The boiler cannot accurately monitor… Medium Engineer View Guide
203 Return Temperature Sensor Fault The return NTC temperature sensor has an open circuit or is giving incorrect readings. Medium Engineer View Guide
301 EEPROM Error — PCB Fault There is an EEPROM (memory chip) fault on the main PCB. The boiler cannot read or… High Engineer View Guide
302 Communication Error — PCB A communication error has occurred on the main PCB, possibly between the PCB and display or… Medium Engineer View Guide
303 Main PCB Error The main Printed Circuit Board has detected an internal error. High Engineer View Guide
304 Too Many Resets — 5 in 15 Minutes The boiler has been reset 5 or more times within 15 minutes and has entered a… Medium DIY View Guide
305 PCB / EEPROM Error The printed circuit board has an internal memory error. The boiler's configuration data may be corrupted. High Engineer View Guide
306 Air Pressure Switch Fault The air pressure switch is not closing when the fan runs. The boiler cannot verify adequate… High Engineer View Guide
501 No Flame Detected / Ignition Failure The most common Ariston fault code. The burner has failed to ignite or the ionisation signal… Medium DIY View Guide
502 Flame Detected With Gas Valve Closed The boiler's ionisation circuit is detecting a flame when the gas valve should be completely closed.… High Engineer View Guide
504 Flame Lift The boiler has detected 'flame lift' — the flame has lifted away from the burner surface,… High Engineer View Guide
5P1 First Ignition Failed (Warning) The first ignition attempt failed — the boiler will try again. This is a warning (non-lockout)… Low DIY View Guide
5P2 Second Ignition Failed (Warning) The second ignition attempt has also failed. The boiler may escalate to a 501 lockout. Medium DIY View Guide
601 Fan Fault The fan is not starting, running too slowly, or has stopped unexpectedly. The boiler cannot safely… High Engineer View Guide
604 Insufficient Fan Speed The boiler fan is not reaching the required speed for safe combustion — preventing ignition. High Engineer View Guide
607 Gas Valve Relay Fault The gas valve relay on the PCB is not operating correctly. The boiler cannot safely control… High Engineer View Guide
610 Thermal Fuse Open The thermal fuse (a one-time safety device) has activated due to extreme overheating. Once blown, it… High Engineer View Guide
612 Fan Speed Incorrect Measurement The fan speed sensor is giving an incorrect reading — fan speed cannot be confirmed as… High Engineer View Guide