Viessmann
Vitodens 333-F 19
Combi Boiler
19kW
2016-present
ErP A
70 fault codes
<p>The Vitodens 333-F 19 is a combi boiler from Viessmann, available at 19kW output. Produced 2016-present.</p>
Vitodens 333-F 19 Fault Codes 70
Code
Description
Severity
Type
02
DHW Sensor Short Circuit
The domestic hot water NTC sensor wiring has a short circuit.
Medium
Engineer
View Guide
05
Return Sensor Short Circuit
The return NTC wiring has a short circuit.
Medium
Engineer
View Guide
0A
Flow Temperature Sensor Fault
The flow NTC is reading outside expected range.
Medium
Engineer
View Guide
0B
Fan Speed Error — Wind Conditions
On Vitodens 200 boilers, code 0B indicates the fan has not idled correctly after an auto-reset,…
Medium
Engineer
View Guide
0C
Flame After Shutdown (Vitodens 200)
On Vitodens 200-W boilers, code 0C indicates a flame signal was still present after the burner…
High
Engineer
View Guide
0F
Boiler Service Required
Not a fault — this is a maintenance reminder indicating the boiler is due for its…
Low
DIY
View Guide
10
DHW Outlet Temperature Sensor Short Circuit
The domestic hot water outlet temperature sensor has a short circuit. The boiler cannot accurately measure…
Medium
Engineer
View Guide
18
Pump Blocked or Not Running
The circulation pump is not responding or is mechanically blocked. Water cannot flow through the heating…
High
Engineer
View Guide
30
Boiler Water Temperature Sensor Short Circuit
The main boiler water temperature sensor (NTC) has short-circuited. On some Viessmann models the burner continues…
Medium
Engineer
View Guide
38
Boiler Water Temperature Sensor Open Circuit
The main boiler water temperature sensor cable has broken or become disconnected.
Medium
Engineer
View Guide
40
Internal Bus Communication Fault
There is a communication fault on the internal data bus between boiler components. The PCB may…
High
Engineer
View Guide
48
eBUS Communication Fault
The eBUS line between boiler and controller has failed.
Medium
Engineer
View Guide
50
No Flame Detected
The boiler has attempted ignition but no flame has been detected by the ionisation electrode.
High
Engineer
View Guide
51
Flame Signal Present Without Gas Release
The ionisation electrode is detecting a flame even though the gas valve should be closed. This…
High
Engineer
View Guide
5C
Outdoor Temperature Sensor Open Circuit
The outdoor temperature sensor wiring has an open circuit or is disconnected.
Low
Engineer
View Guide
71
Outdoor Sensor Short Circuit
The outdoor sensor wiring has a short circuit.
Low
Engineer
View Guide
73
Water Pressure Sensor Fault
The electronic pressure sensor is reading incorrectly.
Medium
Engineer
View Guide
92
Air/Gas Mixture Setting Error
The combustion air/gas ratio is not within the acceptable range. The boiler is not burning fuel…
High
Engineer
View Guide
95
Flame Detected After Shutdown
Flame signal present when gas valve should be closed.
High
Engineer
View Guide
A3
Flue Gas Temperature Limiter
The flue gas temperature has exceeded the safety limit. The boiler has shut down to protect…
High
Engineer
View Guide
A4
Air Lock in Pump / Insufficient Flow (Vitodens 222-F)
On Vitodens 222-F boilers, code A4 indicates an air lock in the internal circulation pump or…
Medium
DIY
View Guide
A6
Low Gas Pressure
The boiler is detecting insufficient gas pressure to operate safely. The gas supply may be interrupted…
High
Engineer
View Guide
A9
Condensate Drain Blocked
The condensate drain is blocked or cannot flow freely. The boiler has detected that condensate is…
Medium
DIY
View Guide
B1
Coding Plug Missing
The boiler's coding plug is missing or not read correctly. The boiler cannot verify its configuration.
High
Engineer
View Guide
C1
Differential Air Pressure Sensor Open Circuit
The differential air pressure sensor has an open circuit, indicating a fault with the sensor or…
High
Engineer
View Guide
CE
Water Pressure Too Low (GB162)
On Worcester Bosch GB162 and Viessmann commercial boilers, CE (code 207) indicates the system water pressure…
Low
DIY
View Guide
E0
Safety Temperature Limiter Triggered
The boiler has exceeded its maximum safe water temperature. The safety limiter has shut down the…
High
Engineer
View Guide
E1
Outdoor Temperature Sensor Fault
The outdoor temperature sensor is not reading correctly. Weather-compensated heating control will not function.
Low
Engineer
View Guide
E4
Burner Start Flame Signal Too Weak
The burner attempted to start but the ionisation signal (flame detection) was too weak or missing.…
Medium
DIY
View Guide
EA
Ignition Failure / No Flame Detected
On Viessmann Vitodens boilers, code EA (or E4 on some models) indicates the burner flame signal…
Medium
DIY
View Guide
F2
Burner Start Fault
The burner has failed to ignite after the start-up sequence. The gas supply, ignition electrode, or…
High
Engineer
View Guide
F3
Flame Signal Lost During Operation
The flame was detected but has been lost during normal operation. This may be caused by…
High
Engineer
View Guide
F4 EE
Frozen Condensate Pipe
Viessmann's specific code for a frozen or blocked condensate pipe. The most common Vitodens winter fault.
Medium
DIY
View Guide
F5
Gas Pressure Switch / No Gas Pressure
The gas pressure switch is showing no gas pressure, or there is an electrical connection fault…
High
Engineer
View Guide
F6
Low Water Pressure
The system water pressure has dropped below the minimum safe level. The boiler cannot circulate water…
Low
DIY
View Guide
FC
Gas Valve Fault / Flue Blocked
On Viessmann boilers, code FC indicates either a gas valve fault, a faulty modulation valve control,…
High
Engineer
View Guide
FE
EMC Interference / PCB Fault
Strong electromagnetic interference (EMC) nearby or a faulty main PCB is causing the burner to block…
High
Engineer
View Guide