Regular 12kW 1988-2000 ErP D 77 fault codes

<p>The Classic FF 240 is a combi boiler from Ideal, available at 12kW output. Produced 1988-2000.</p>

Classic FF 240 Fault Codes 77

Code Description Severity Type
C0 Fan Fault — Fan Not Running The fan has failed to start or is not reaching operating speed. C0 is a lockout… High Engineer View Guide
C0 0 Fan Not Running at Start (Sub-code) The fan is not running at the point in the start sequence where it is required. High Engineer View Guide
C1 Flue Temperature Too High The flue gas temperature has exceeded the safe limit. The boiler has shut down to prevent… High Engineer View Guide
C2 Fan Fault — Speed Out of Range The fan speed is outside the expected operating range — either too slow or too fast. High Engineer View Guide
C3 Air Pressure Switch Open The air pressure switch is not closing when the fan runs. The boiler cannot confirm adequate… High Engineer View Guide
C4 Diverter Valve Fault The diverter valve is stuck or not switching. Medium Engineer View Guide
C5 Rapid Temperature Rise Flow temperature rising too quickly, indicating poor circulation. High Engineer View Guide
C6 Flow/Return Differential Too Large The temperature gap between flow and return is abnormal. Medium Engineer View Guide
C7 Outdoor Sensor Fault The outdoor temperature sensor is faulty. Low Engineer View Guide
C8 eBUS Communication Fault The eBUS line has a fault. Medium Engineer View Guide
C9 EEPROM Error PCB memory error. High Engineer View Guide
F0 Frost Protection Active Frost protection cycles are running. Medium DIY View Guide
F1 Low Water Pressure The boiler's water pressure has dropped below the minimum operating level. One of the most common… Low DIY View Guide
F10 DHW Temperature Sensor Fault The domestic hot water temperature sensor has a fault. On combi boilers, this prevents safe hot… Medium Engineer View Guide
F11 Cylinder Sensor Fault The hot water cylinder temperature sensor has a fault. Relevant on system boilers paired with a… Medium Engineer View Guide
F12 Flame Loss During Operation The boiler had a stable flame but lost it during operation. This can be caused by… High Engineer View Guide
F13 Gas Pressure Sensor Fault The gas pressure sensor is giving an out-of-range reading, preventing safe operation. High Engineer View Guide
F14 Gas Valve Fault The gas valve is not responding correctly to commands from the PCB. High Engineer View Guide
F15 PCB Communication Fault The printed circuit board (PCB) has an internal communication error. Key boiler components cannot communicate correctly. High Engineer View Guide
F16 Fan Fault The fan is not running at the correct speed or has stopped. The boiler cannot safely… High Engineer View Guide
F17 Pump Over-Run Fault The pump did not stop after the burner shut down. Medium Engineer View Guide
F18 Condensate Blocked The condensate drain is blocked or frozen. Medium DIY View Guide
F19 Flue Gas Overheat The flue gas temperature is too high. High Engineer View Guide
F2 Flame Loss The boiler has lost its flame during operation or failed to ignite. Medium DIY View Guide
F20 Pressure Sensor Fault The electronic water pressure sensor is giving incorrect readings. Medium Engineer View Guide
F21 Pump Fault The circulation pump is not running or is blocked. High Engineer View Guide
F22 Gas Valve Fault The gas valve is not responding correctly. High Engineer View Guide
F23 Flame Detected After Shutdown Flame signal with gas valve closed. High Engineer View Guide
F24 Outdoor Sensor Fault Outdoor sensor faulty or disconnected. Low Engineer View Guide
F25 eBUS Fault Communication line fault. Medium Engineer View Guide
F26 Phase/Neutral Reversed Electrical polarity reversed. High Engineer View Guide
F27 EEPROM Error PCB memory error. High Engineer View Guide
F28 Coding Plug Fault Coding plug unreadable. High Engineer View Guide
F29 Mains Voltage Fault Voltage outside range. Medium Engineer View Guide
F3 Fan Fault The boiler fan is not operating at the required speed, preventing safe ignition. High Engineer View Guide
F30 Combustion Fault Air/gas outside limits. High Engineer View Guide
F4 Flow Thermistor Fault The flow temperature sensor (thermistor) is giving an incorrect reading or has failed. Medium Engineer View Guide
F5 Return Thermistor Fault The return temperature sensor is giving an incorrect reading or has failed. Medium Engineer View Guide
F6 Outside Sensor Fault The external temperature sensor (used for weather compensation) is faulty or not connected. This does not… Low Engineer View Guide
F7 Low Mains Voltage The mains voltage supply to the boiler has dropped below the safe minimum (185V). Medium Engineer View Guide
F8 Flow Thermistor - Out of Range High The flow temperature sensor is reading higher than its maximum expected value, indicating a sensor fault… High Engineer View Guide
F9 Unconfigured PCB The Printed Circuit Board has not been configured correctly. This almost always occurs after a PCB… Medium Engineer View Guide
FA Flow/Return Sensors Reversed (Regular Boilers) On Ideal Logic Max and Logic Plus regular (heat-only) boilers, code FA indicates the flow and… Medium Engineer View Guide
FD Condensate Blocked / Frozen The condensate drain system is blocked or frozen. FD is Ideal's code for a blocked condensate… Medium DIY View Guide
FN Flame Loss (Alternative Code) On some Ideal models, FN is displayed alongside or instead of F2 to indicate flame loss… Medium DIY View Guide
FU Temperature Difference Too High — Check Isolation Valves The temperature difference between the flow and return is greater than 50°C. The boiler is blocking… Medium DIY View Guide
GV Gas Valve Fault The gas valve is not responding to commands from the PCB. High Engineer View Guide
HL Overheat Lockout The boiler exceeded maximum safe temperature. High Engineer View Guide
HT DHW Overheat The domestic hot water temperature has exceeded safe limits. High Engineer View Guide
L0 Safety Limit Lockout (Generic) A safety device has operated. This is a catch-all lockout code when a specific fault cannot… High Engineer View Guide
L1 Flow Overheat / No Water Flow Lockout The boiler has locked out because the flow temperature is too high or no water is… High Engineer View Guide
L10 Overheat Lockout — Maximum Temperature Exceeded The boiler has reached its absolute maximum temperature and locked out. A more severe overheat than… High Engineer View Guide
L11 Central Heating Thermistor Fault The central heating NTC thermistor is reading outside its normal range. The sensor may have developed… Medium Engineer View Guide
L12 Return NTC Fault Return NTC sensor faulty. Medium Engineer View Guide
L13 DHW NTC Fault Hot water sensor faulty. Medium Engineer View Guide
L14 Flow NTC Short Circuit Flow NTC wiring shorted. Medium Engineer View Guide
L15 Return NTC Short Circuit Return NTC wiring shorted. Medium Engineer View Guide
L16 DHW NTC Short Circuit DHW NTC wiring shorted. Medium Engineer View Guide
L17 APS Open Air pressure switch not confirming airflow. High Engineer View Guide
L18 Rapid Temperature Rise Flow temp rising too fast. High Engineer View Guide
L19 Flow/Return Differential Fault Temperature gap abnormal. Medium Engineer View Guide
L2 Ignition Lockout The boiler has locked out after failing to ignite or losing its flame. A persistent version… Medium DIY View Guide
L20 Condensate Blocked Condensate drain blocked. Medium DIY View Guide
L3 Fan Lockout The boiler fan has failed to reach the required speed after multiple attempts. High Engineer View Guide
L4 Overheat Lockout The boiler's safety overheat thermostat has triggered a lockout due to excessively high temperatures. High Engineer View Guide
L5 Too Many Resets The boiler has been reset 5 times within 15 minutes and has entered a protective lockout. Medium DIY View Guide
L6 False Flame Lockout The boiler has detected an ionisation signal when the gas valve should be closed. This is… High Engineer View Guide
L7 DHW Thermistor Lockout The domestic hot water temperature sensor has caused a lockout — either due to a sensor… High Engineer View Guide
L8 Flue Temperature Lockout The flue gas temperature sensor has detected an unsafe temperature, causing a lockout. High Engineer View Guide
L9 PCB Fault / Unconfigured The PCB has an internal fault or has not been configured correctly. L9 is the lockout… High Engineer View Guide
LC Too Many Resets (5 Within 15 Minutes) The boiler has been reset 5 or more times within 15 minutes and has entered a… Medium DIY View Guide
LE Low Water Pressure System pressure is below minimum. Low DIY View Guide
LF Low Gas Pressure Warning The boiler has detected that the gas supply pressure is lower than expected, which may cause… Medium Engineer View Guide
LN Flame Loss Lockout (Alternative Code) On some Ideal models, LN is a lockout version of FN/F2, indicating repeated flame loss requiring… Medium DIY View Guide
LP Low Pressure Lockout System pressure critically low — boiler locked out. Medium DIY View Guide
PF PCB Fault The printed circuit board has an internal error. High Engineer View Guide
SE Sensor Error One or more NTC temperature sensors are reading outside expected range. Medium Engineer View Guide