System Boiler 24kW 2010-2018 ErP A 90 fault codes

<p>The DOMIproject S24D is a system boiler from Ferroli, available at 24kW output. Produced 2010-2018.</p>

DOMIproject S24D Fault Codes 90

Code Description Severity Type
A01 Ignition Failure / No Flame The boiler has failed to ignite — no flame was detected after the ignition sequence. This… Medium DIY View Guide
A02 Flame Loss During Operation The boiler ignited but then lost its flame during normal operation. Common causes include gas pressure… Medium DIY View Guide
A03 Safety Thermostat Lockout The boiler safety thermostat has triggered due to overheating. High Engineer View Guide
A04 False Ionisation / Flame Detected Without Demand The boiler's ionisation circuit is detecting a flame when none should be present. A serious safety… High Engineer View Guide
A05 Overheat Lockout The safety thermostat has detected excessively high temperatures and shut the boiler down. High Engineer View Guide
A06 Overheat Lockout — Secondary A secondary overheat safety device has activated. High Engineer View Guide
A07 Fan Fault The fan is not operating at the required speed or has stopped. High Engineer View Guide
A08 Fan Overspeed The fan is running above its rated maximum speed. High Engineer View Guide
A09 Fan Not Responding to Start Command The fan has not started within the required time after the PCB sent the start signal. High Engineer View Guide
A10 Flow NTC Open Circuit The flow temperature sensor circuit is broken. Medium Engineer View Guide
A11 Return NTC Open Circuit The return temperature sensor circuit is broken. Medium Engineer View Guide
A12 DHW NTC Short Circuit The hot water sensor wiring has shorted. Medium Engineer View Guide
A13 Flow NTC Sensor Fault The flow temperature sensor has failed or has a wiring fault. Medium Engineer View Guide
A14 Return NTC Sensor Fault The return temperature sensor has failed or has a wiring fault. Medium Engineer View Guide
A15 DHW Outlet Sensor Fault The domestic hot water outlet temperature sensor has failed or has a wiring issue. Medium Engineer View Guide
A16 Gas Valve Lockout — Failed to Close The gas valve has failed to close correctly after the burner should have stopped. Safety-critical. High Engineer View Guide
A17 Gas Valve Fault The gas valve is not responding to commands. High Engineer View Guide
A18 PCB Fault Internal error on the printed circuit board. High Engineer View Guide
A19 PCB Fault — Communication Error An internal communication error has been detected on the PCB. High Engineer View Guide
A20 Condensate Siphon Blocked The internal condensate siphon is blocked with scale, debris, or ice. Medium Engineer View Guide
A21 Flue Temperature Too High Flue gas temperature has exceeded the limit. High Engineer View Guide
A22 Low Gas Pressure Insufficient gas supply pressure detected. High Engineer View Guide
A23 Pump Fault The pump is not operating correctly. High Engineer View Guide
A24 Pump Over-Speed The pump is running faster than expected. Medium Engineer View Guide
A25 Three-Way Valve Fault The diverter valve is not switching. Medium Engineer View Guide
A26 Condensate Blocked The condensate drain is blocked or frozen. Medium DIY View Guide
A27 PCB Fault The main PCB has detected an internal fault. High Engineer View Guide
A28 Flame Instability The flame signal is fluctuating. High Engineer View Guide
A29 Fan Fault The fan is not running correctly. High Engineer View Guide
A30 Air Pressure Switch Fault The APS is not detecting correct airflow. High Engineer View Guide
A31 Flow/Return Sensor Reversed The sensors are fitted to the wrong pipes. Medium Engineer View Guide
A61 PCB AGC01 Internal Error On Ferroli Bluehelix Tech boilers, A61 indicates an internal error in the main PCB (AGC01 controller). High Engineer View Guide
A62 No Communication Between PCB and Gas Valve On Ferroli boilers, A62 indicates there is no communication between the main PCB and the electronic… High Engineer View Guide
A64 Maximum Consecutive Resets Exceeded On Ferroli Bluehelix Tech boilers, A64 means the maximum number of consecutive resets has been reached.… High Engineer View Guide
D1 Diverter Valve Fault The diverter valve (which switches water flow between heating and hot water) appears to not be… Medium Engineer View Guide
F01 Low Water Pressure Warning A warning (non-lockout) version of the low pressure fault on some Ferroli models. The boiler may… Low DIY View Guide
F02 Overheat Lockout The boiler exceeded its safe temperature. High Engineer View Guide
F03 Low Water Pressure (Warning) System pressure is approaching the minimum — a warning before lockout occurs. Low DIY View Guide
F04 Ionisation Fault No flame detected during ignition. High Engineer View Guide
F05 Air Pressure Switch Error The air pressure switch is not registering correctly — this switch confirms the fan has reached… High Engineer View Guide
F06 Flue Sensor Fault The flue gas NTC sensor is faulty. Medium Engineer View Guide
F07 High Flue Gas Temperature The flue gas probe (exchanger probe) has detected an excessively high temperature for more than 2… High Engineer View Guide
F08 Overtemperature Protection — Flow Sensor On Ferroli Bluehelix Tech boilers, F08 indicates the overtemperature protection has activated based on the heating… High Engineer View Guide
F09 Overtemperature Protection — Return Sensor On Ferroli Bluehelix Tech boilers, F09 indicates the overtemperature protection has activated based on the return… High Engineer View Guide
F10 Flue Temperature Too High The flue gas temperature sensor has detected temperatures above safe limits. High Engineer View Guide
F11 Return Sensor Fault On Ferroli boilers, F11 indicates the return temperature sensor has a wiring fault (shorted or disconnected)… Medium Engineer View Guide
F12 DHW Sensor Fault The domestic hot water temperature sensor has a wiring fault (shorted or disconnected) or has failed.… Medium Engineer View Guide
F13 Flue Probe Fault On Ferroli boilers, F13 indicates the flue gas probe has a wiring fault (shorted or disconnected)… Medium Engineer View Guide
F14 Flow Sensor 2 / Fan Problem Fault On some Ferroli models, F14 indicates either a secondary delivery sensor fault (DOMIcondens) or a fan… Medium Engineer View Guide
F15 Supply Voltage Low (Modena HE) On Ferroli Modena HE combi boilers, F15 indicates the supply voltage has dropped below 170V. Medium Engineer View Guide
F16 Low Water Pressure System pressure is below minimum. Low DIY View Guide
F17 No Water Circulation The pump is not circulating water. High Engineer View Guide
F18 Rapid Temperature Rise Flow temperature rising too fast. High Engineer View Guide
F20 DHW NTC Open Circuit The hot water sensor circuit is broken. Medium Engineer View Guide
F21 Outdoor Sensor Fault The outdoor sensor is faulty or disconnected. Low Engineer View Guide
F22 Low Water Pressure (Pressure Switch) The pressure switch has detected dangerously low pressure. Medium Engineer View Guide
F23 Flow/Return Differential Too Large The temperature gap is too high. Medium Engineer View Guide
F24 Frost Protection Active Frost protection cycles are running. Medium DIY View Guide
F25 PCB EEPROM Error The PCB memory is corrupted. High Engineer View Guide
F26 Gas Valve Relay Fault The PCB relay controlling the gas valve has failed. High Engineer View Guide
F27 Flame Detected After Shutdown A flame signal is present after the gas valve should be closed. High Engineer View Guide
F28 Flame Loss (Condensate Related) Flame loss associated with a blocked or frozen condensate pipe — Ferroli uses F28 specifically for… Medium DIY View Guide
F29 Ignition Electrode Worn The ignition electrode spark is weak. High Engineer View Guide
F30 External Thermostat Fault The external thermostat signal is incorrect. Medium Engineer View Guide
F31 eBUS Communication Fault The eBUS communication line has failed. Medium Engineer View Guide
F32 Mains Voltage Error Mains supply voltage is outside range. Medium Engineer View Guide
F33 Combustion Quality Fault Air/gas mixture is outside limits. High Engineer View Guide
F34 Low Supply Voltage On Ferroli boilers, F34 indicates the mains supply voltage has dropped below 170V — too low… Medium Engineer View Guide
F35 Incorrect Mains Frequency On Ferroli boilers, F35 indicates an incorrect or irregular mains power frequency (should be 50Hz in… Medium Engineer View Guide
F36 Return NTC Short Circuit The return sensor wiring has shorted. Medium Engineer View Guide
F37 Low Water Pressure The system water pressure has dropped below the minimum required level. Low DIY View Guide
F38 Flow NTC Short Circuit The flow sensor wiring has shorted. Medium Engineer View Guide
F39 External Temperature Probe Fault The optional external temperature probe (for weather compensation) has a wiring fault or has been disconnected… Low Engineer View Guide
F40 Pressure Sensor Fault The electronic pressure sensor gives wrong readings. Medium Engineer View Guide
F41 Maximum Delta-T Protection Activated On Ferroli Bluehelix Tech boilers, F41 indicates the maximum allowable temperature difference between flow and return… High Engineer View Guide
F42 Sensor Control Protection Activated On Ferroli Bluehelix Tech, F42 indicates the sensor control protection has activated due to heating or… High Engineer View Guide
F43 Heat Exchanger Protection — No Circulation On Ferroli boilers, F43 indicates the heat exchanger protection has activated due to no water circulation… High Engineer View Guide
F44 Cylinder Sensor Fault The cylinder NTC is faulty (system boilers). Medium Engineer View Guide
F45 Coding Plug Missing The boiler coding plug is missing. High Engineer View Guide
F46 Phase/Neutral Reversed The electrical supply has reversed polarity. High Engineer View Guide
F47 Pump Stuck The pump has seized. High Engineer View Guide
F48 DHW Flow Switch Fault The DHW flow switch is not detecting water flow. Medium Engineer View Guide
F49 Pump Over-Run Fault The pump did not stop after the burner shut down. Medium Engineer View Guide
F50 Diverter Valve Timeout The diverter did not switch in time. Medium Engineer View Guide
F51 Flame Signal Too Weak The ionisation current is below minimum. High Engineer View Guide
F52 Controller Internal Error On Ferroli Modena HE combi boilers, F52 indicates the controller has an internal error. High Engineer View Guide
F53 Fan Speed Error Fan speed out of range. High Engineer View Guide
F54 Gas Valve Step Error The gas valve stepper motor is not responding. High Engineer View Guide
F55 Room Controller Lost Communication with the room controller is lost. Low Engineer View Guide
F56 Calibration Error / Incomplete Calibration On Ferroli Bluehelix Tech boilers, F56 indicates the auto-calibration procedure did not complete correctly, or there… Medium Engineer View Guide

Are you a Gas Safe Engineer?

Access technical fault data, wiring diagrams, and parts lists. Free for verified Gas Safe engineers.