Promax System 24kW

System Boiler 24kW 2012-2020 ErP A 74 fault codes

<p>The Promax System 24kW is a system boiler from Potterton, available at 24kW output. Produced 2012-2020.</p>

Promax System 24kW Fault Codes 74

Code Description Severity Type
E09 Gas Valve Wiring Fault There is a fault in the wiring to the gas valve — either the connection cable… High Engineer View Guide
E10 Flow Sensor Fault The flow temperature sensor has failed or has a wiring fault. Medium Engineer View Guide
E109 Poor Circulation / Pre-Circulation Fault The boiler has detected insufficient water circulation during its pre-circulation check. Usually caused by airlocks, closed… Medium Engineer View Guide
E11 Return Sensor Fault The return temperature sensor has failed or has a wiring fault. Medium Engineer View Guide
E110 Overheat Lockout The boiler has overheated and the safety thermostat has triggered. High Engineer View Guide
E116 High Flow Temperature The boiler flow temperature exceeded its maximum safe level. High Engineer View Guide
E117 Gas Valve Fault The gas valve has a fault — it may not be opening, closing, or responding to… High Engineer View Guide
E119 Low Water Pressure System pressure has dropped below the required minimum of 0.5 bar. Shared with Baxi boilers —… Low DIY View Guide
E12 Differential Water Flow Switch — Remains Open The differential water flow switch is remaining open when it should be closed. Indicates a circulation… Medium Engineer View Guide
E125 Primary Circulation Fault There is insufficient water circulation in the primary heating circuit. Medium Engineer View Guide
E128 Frequent Flame Failure The boiler has lost its flame 12 times in succession and entered a safety lockout. High Engineer View Guide
E129 Frequent Flame Loss — Safety Lockout The boiler has experienced repeated flame loss during operation — a persistent version of the flame… High Engineer View Guide
E13 Differential Water Flow Switch — Remains Closed The differential water flow switch is stuck in the closed position. Indicates a faulty switch or… Medium Engineer View Guide
E130 Flue Thermostat Tripped The flue safety thermostat has triggered due to excessively high flue gas temperatures. High Engineer View Guide
E131 Flue Overheat The flue temperature has reached an unsafe level, triggering the flue thermostat. High Engineer View Guide
E133 Ignition Failure / Frozen Condensate The boiler has failed to ignite. In winter, the most common cause is a frozen condensate… Medium DIY View Guide
E134 Gas Valve Open Without Gas The gas valve has been commanded open but no gas has been detected flowing — the… High Engineer View Guide
E135 Air Pressure Switch Fault The air pressure switch is not registering correctly — this confirms the fan is running before… High Engineer View Guide
E14 Low Gas Pressure The boiler is detecting insufficient gas supply pressure. High Engineer View Guide
E15 Gas Valve Command Fault There is a fault with the gas valve command signal from the PCB to the valve.… High Engineer View Guide
E151 PCB Error (Type 1) The PCB has detected an internal fault of type 1. High Engineer View Guide
E152 PCB Error (Type 2) The PCB has detected an internal fault of type 2. A more serious variant than E151. High Engineer View Guide
E154 Flow/Return Sensor Temperature Test Failure The boiler has performed an internal temperature sensor cross-check and found the flow or return sensor… Medium Engineer View Guide
E16 Fan Fault The fan is not running at the correct speed. High Engineer View Guide
E160 Fan Fault The boiler fan is not operating at the correct speed or has stopped working altogether. High Engineer View Guide
E161 Fan Fault (Secondary) A secondary fan fault code on Potterton boilers — fan speed or operation is outside expected… High Engineer View Guide
E163 DHW NTC Sensor Fault The domestic hot water temperature sensor has a fault — short circuit or open circuit. On… Medium Engineer View Guide
E164 Pressure Sensor Fault The water pressure sensor is giving an out-of-range signal. May indicate a blocked or failed sensor. Medium Engineer View Guide
E168 PCB Lockout / Unspecified Fault The PCB has detected a fault it cannot specifically identify and has locked out the boiler. High Engineer View Guide
E18 Ignition Electrode Fault The ignition electrode is worn or not sparking. High Engineer View Guide
E19 Gas Valve Fault The gas valve is not responding correctly. High Engineer View Guide
E193 Circulation Fault (Secondary) A secondary circulation fault indicating an issue with water flow that has not yet caused full… Medium Engineer View Guide
E20 Flame Failure Lockout The boiler has failed to detect a flame after the ignition sequence. Medium DIY View Guide
E21 Flow Sensor Short Circuit The flow NTC sensor has a short circuit. Medium Engineer View Guide
E22 Flow Sensor Open Circuit The flow NTC sensor has an open circuit. Medium Engineer View Guide
E220 Gas Valve Not Opening The gas valve has received the signal to open but hasn't responded correctly. High Engineer View Guide
E23 Return Sensor Short Circuit The return NTC sensor has a short circuit. Medium Engineer View Guide
E24 Return Sensor Open Circuit The return NTC sensor has an open circuit. Medium Engineer View Guide
E25 DHW Sensor Short Circuit The DHW NTC sensor has a short circuit. Medium Engineer View Guide
E26 DHW Sensor Open Circuit The DHW NTC sensor has an open circuit. Medium Engineer View Guide
E27 Air Pressure Switch Fault The APS is not confirming airflow. High Engineer View Guide
E270 Dry Fire Detected The boiler has fired or attempted to fire without detecting adequate water circulation — a 'dry… High Engineer View Guide
E28 Frozen Condensate / Flame Failure (Winter) Flame failure associated with a frozen condensate pipe in cold weather. Identical to Baxi E28 —… Medium DIY View Guide
E30 Diverter Valve Fault The diverter valve is stuck or not switching. Medium Engineer View Guide
E31 PCB Communication Fault Internal PCB communication error. High Engineer View Guide
E317 Wrong Power Supply Frequency The boiler is detecting an incorrect mains power frequency (should be 50Hz in the UK). This… Medium Engineer View Guide
E32 Pump Fault The pump is not running or is blocked. High Engineer View Guide
E321 Hot Water Thermistor Fault The hot water temperature thermistor has a fault — applies to store/system boilers with a hot… Medium Engineer View Guide
E33 Flame Instability The flame signal is fluctuating during operation. High Engineer View Guide
E34 Condensate Blocked The condensate drain is blocked or frozen. Medium DIY View Guide
E35 Rapid Temperature Rise Flow temperature is rising too fast, indicating circulation problems. High Engineer View Guide
E36 Pressure Sensor Fault The electronic pressure sensor is reading incorrectly. Medium Engineer View Guide
E37 Safety Thermostat Open The safety thermostat wire or connection is open. High Engineer View Guide
E38 Flue Gas Overheat The flue gas temperature has exceeded safe limits. High Engineer View Guide
E384 False Flame — Gas Valve Off The boiler has detected an ionisation signal (flame) when the gas valve should be completely closed.… High Engineer View Guide
E385 Low Voltage — Under 195V The mains voltage supply to the boiler has dropped below 195V — below the minimum operating… Medium Engineer View Guide
E39 Frost Protection Active The boiler is running frost protection cycles. Medium DIY View Guide
E40 Thermistor / Sensor Short Circuit A temperature sensor has short-circuited, causing the boiler to lock out. Medium Engineer View Guide
E41 Three-Way Valve Timeout The three-way valve did not switch within the expected time. Medium Engineer View Guide
E42 Outdoor Sensor Fault The outdoor temperature sensor is faulty or disconnected. Low Engineer View Guide
E43 eBUS Fault The eBUS communication line has a fault. Medium Engineer View Guide
E430 Water Pressure Test / Test Failed The boiler is performing a water pressure test (normal on commissioning) or the test has failed,… Medium Engineer View Guide
E44 Mains Voltage Fault The mains voltage is outside acceptable range. Medium Engineer View Guide
E45 EEPROM Error PCB memory error. High Engineer View Guide
E46 Coding Plug Fault The boiler coding plug cannot be read. High Engineer View Guide
E47 Pump Kickback Fault The pump failed to restart after a pause. Medium Engineer View Guide
E48 Phase/Neutral Reversed The electrical supply has reversed polarity. High Engineer View Guide
E50 DHW NTC Sensor Fault The domestic hot water temperature sensor has a fault on combi boiler models. Medium Engineer View Guide
E53 Condensate Pipe Blocked The condensate system is blocked, preventing the boiler from operating safely. Medium DIY View Guide
E55 Calibration Required The boiler requires calibration — this code appears on auto-calibrating models when the combustion setup needs… Medium Engineer View Guide
E78 Water Pressure Sensor Fault The water pressure sensor is giving an incorrect reading. May indicate a blocked or failed sensor. Medium Engineer View Guide
E83 Room Controller Communication Fault The boiler cannot communicate with the room controller — may be a wiring fault or controller… Medium Engineer View Guide
E84 Room Controller Not Recognised The room controller connected to the boiler is not being recognised by the PCB. Medium Engineer View Guide
E92 Combustion Test Alarm During Auto-Setting An alarm has been triggered during the automatic combustion calibration process. The auto-setting procedure detected a… High Engineer View Guide