Potterton
Promax SL 28kW
Combi Boiler
28kW
2012-2020
ErP A
74 fault codes
<p>The Promax SL 28kW is a combi boiler from Potterton, available at 28kW output. Produced 2012-2020.</p>
Promax SL 28kW Fault Codes 74
Code
Description
Severity
Type
E09
Gas Valve Wiring Fault
There is a fault in the wiring to the gas valve — either the connection cable…
High
Engineer
View Guide
E10
Flow Sensor Fault
The flow temperature sensor has failed or has a wiring fault.
Medium
Engineer
View Guide
E109
Poor Circulation / Pre-Circulation Fault
The boiler has detected insufficient water circulation during its pre-circulation check. Usually caused by airlocks, closed…
Medium
Engineer
View Guide
E11
Return Sensor Fault
The return temperature sensor has failed or has a wiring fault.
Medium
Engineer
View Guide
E110
Overheat Lockout
The boiler has overheated and the safety thermostat has triggered.
High
Engineer
View Guide
E116
High Flow Temperature
The boiler flow temperature exceeded its maximum safe level.
High
Engineer
View Guide
E117
Gas Valve Fault
The gas valve has a fault — it may not be opening, closing, or responding to…
High
Engineer
View Guide
E119
Low Water Pressure
System pressure has dropped below the required minimum of 0.5 bar. Shared with Baxi boilers —…
Low
DIY
View Guide
E12
Differential Water Flow Switch — Remains Open
The differential water flow switch is remaining open when it should be closed. Indicates a circulation…
Medium
Engineer
View Guide
E125
Primary Circulation Fault
There is insufficient water circulation in the primary heating circuit.
Medium
Engineer
View Guide
E128
Frequent Flame Failure
The boiler has lost its flame 12 times in succession and entered a safety lockout.
High
Engineer
View Guide
E129
Frequent Flame Loss — Safety Lockout
The boiler has experienced repeated flame loss during operation — a persistent version of the flame…
High
Engineer
View Guide
E13
Differential Water Flow Switch — Remains Closed
The differential water flow switch is stuck in the closed position. Indicates a faulty switch or…
Medium
Engineer
View Guide
E130
Flue Thermostat Tripped
The flue safety thermostat has triggered due to excessively high flue gas temperatures.
High
Engineer
View Guide
E131
Flue Overheat
The flue temperature has reached an unsafe level, triggering the flue thermostat.
High
Engineer
View Guide
E133
Ignition Failure / Frozen Condensate
The boiler has failed to ignite. In winter, the most common cause is a frozen condensate…
Medium
DIY
View Guide
E134
Gas Valve Open Without Gas
The gas valve has been commanded open but no gas has been detected flowing — the…
High
Engineer
View Guide
E135
Air Pressure Switch Fault
The air pressure switch is not registering correctly — this confirms the fan is running before…
High
Engineer
View Guide
E14
Low Gas Pressure
The boiler is detecting insufficient gas supply pressure.
High
Engineer
View Guide
E15
Gas Valve Command Fault
There is a fault with the gas valve command signal from the PCB to the valve.…
High
Engineer
View Guide
E152
PCB Error (Type 2)
The PCB has detected an internal fault of type 2. A more serious variant than E151.
High
Engineer
View Guide
E154
Flow/Return Sensor Temperature Test Failure
The boiler has performed an internal temperature sensor cross-check and found the flow or return sensor…
Medium
Engineer
View Guide
E160
Fan Fault
The boiler fan is not operating at the correct speed or has stopped working altogether.
High
Engineer
View Guide
E161
Fan Fault (Secondary)
A secondary fan fault code on Potterton boilers — fan speed or operation is outside expected…
High
Engineer
View Guide
E163
DHW NTC Sensor Fault
The domestic hot water temperature sensor has a fault — short circuit or open circuit. On…
Medium
Engineer
View Guide
E164
Pressure Sensor Fault
The water pressure sensor is giving an out-of-range signal. May indicate a blocked or failed sensor.
Medium
Engineer
View Guide
E168
PCB Lockout / Unspecified Fault
The PCB has detected a fault it cannot specifically identify and has locked out the boiler.
High
Engineer
View Guide
E18
Ignition Electrode Fault
The ignition electrode is worn or not sparking.
High
Engineer
View Guide
E193
Circulation Fault (Secondary)
A secondary circulation fault indicating an issue with water flow that has not yet caused full…
Medium
Engineer
View Guide
E20
Flame Failure Lockout
The boiler has failed to detect a flame after the ignition sequence.
Medium
DIY
View Guide
E220
Gas Valve Not Opening
The gas valve has received the signal to open but hasn't responded correctly.
High
Engineer
View Guide
E23
Return Sensor Short Circuit
The return NTC sensor has a short circuit.
Medium
Engineer
View Guide
E24
Return Sensor Open Circuit
The return NTC sensor has an open circuit.
Medium
Engineer
View Guide
E270
Dry Fire Detected
The boiler has fired or attempted to fire without detecting adequate water circulation — a 'dry…
High
Engineer
View Guide
E28
Frozen Condensate / Flame Failure (Winter)
Flame failure associated with a frozen condensate pipe in cold weather. Identical to Baxi E28 —…
Medium
DIY
View Guide
E317
Wrong Power Supply Frequency
The boiler is detecting an incorrect mains power frequency (should be 50Hz in the UK). This…
Medium
Engineer
View Guide
E321
Hot Water Thermistor Fault
The hot water temperature thermistor has a fault — applies to store/system boilers with a hot…
Medium
Engineer
View Guide
E35
Rapid Temperature Rise
Flow temperature is rising too fast, indicating circulation problems.
High
Engineer
View Guide
E36
Pressure Sensor Fault
The electronic pressure sensor is reading incorrectly.
Medium
Engineer
View Guide
E37
Safety Thermostat Open
The safety thermostat wire or connection is open.
High
Engineer
View Guide
E384
False Flame — Gas Valve Off
The boiler has detected an ionisation signal (flame) when the gas valve should be completely closed.…
High
Engineer
View Guide
E385
Low Voltage — Under 195V
The mains voltage supply to the boiler has dropped below 195V — below the minimum operating…
Medium
Engineer
View Guide
E40
Thermistor / Sensor Short Circuit
A temperature sensor has short-circuited, causing the boiler to lock out.
Medium
Engineer
View Guide
E41
Three-Way Valve Timeout
The three-way valve did not switch within the expected time.
Medium
Engineer
View Guide
E42
Outdoor Sensor Fault
The outdoor temperature sensor is faulty or disconnected.
Low
Engineer
View Guide
E430
Water Pressure Test / Test Failed
The boiler is performing a water pressure test (normal on commissioning) or the test has failed,…
Medium
Engineer
View Guide
E50
DHW NTC Sensor Fault
The domestic hot water temperature sensor has a fault on combi boiler models.
Medium
Engineer
View Guide
E53
Condensate Pipe Blocked
The condensate system is blocked, preventing the boiler from operating safely.
Medium
DIY
View Guide
E55
Calibration Required
The boiler requires calibration — this code appears on auto-calibrating models when the combustion setup needs…
Medium
Engineer
View Guide
E78
Water Pressure Sensor Fault
The water pressure sensor is giving an incorrect reading. May indicate a blocked or failed sensor.
Medium
Engineer
View Guide
E83
Room Controller Communication Fault
The boiler cannot communicate with the room controller — may be a wiring fault or controller…
Medium
Engineer
View Guide
E84
Room Controller Not Recognised
The room controller connected to the boiler is not being recognised by the PCB.
Medium
Engineer
View Guide
E92
Combustion Test Alarm During Auto-Setting
An alarm has been triggered during the automatic combustion calibration process. The auto-setting procedure detected a…
High
Engineer
View Guide