Glow-worm

Betacom 4 28kW

Combi Boiler 28kW 2014-2020 ErP A 101 fault codes

<p>The Betacom 4 28kW is a combi boiler from Glow-worm, available at 28kW output. Produced 2014-2020.</p>

Betacom 4 28kW Fault Codes 101

Code Description Severity Type
F.00 Flow Temperature Sensor Fault (Energy Range) On Glow-worm Energy range boilers, F.00 indicates a fault with the flow temperature sensor. Identical to… Medium Engineer View Guide
F.10 Flow Temperature Sensor Short Circuit (Energy) On Glow-worm Energy boilers, F.10 indicates the flow temperature sensor has short-circuited. Medium Engineer View Guide
F.11 Return Temperature Sensor Short Circuit (Energy) On Glow-worm Energy boilers, F.11 indicates the return temperature sensor has short-circuited. Medium Engineer View Guide
F.20 Safety Overheat (Energy Range) On Glow-worm Energy boilers, F.20 indicates the safety overheat temperature has been reached. The boiler has… High Engineer View Guide
F.25 Flue Gas Temperature Too High (Energy Range) On Glow-worm Energy boilers, F.25 indicates the flue gas temperature has exceeded safe limits. High Engineer View Guide
F.27 Flame Detection Fault (Energy Range) On Glow-worm Energy boilers, F.27 indicates a fault in the flame detection circuit. Shared with older… High Engineer View Guide
F.33 Air Pressure Switch Fault (Energy Range) On Glow-worm Energy boilers, F.33 indicates an air pressure switch fault — the switch is not… High Engineer View Guide
F.82 Gas Valve Switch-Off Control Fault (Energy Range) On Glow-worm Energy boilers, F.82 indicates a fault in the gas valve switch-off control circuit. High Engineer View Guide
F.83 EEPROM Fault (Energy Range) On Glow-worm Energy boilers, F.83 indicates an EEPROM (memory) fault — the PCB electronics are defective. High Engineer View Guide
F.87 Electrode Fault (Energy Range) On Glow-worm Energy boilers, F.87 indicates an ignition or sensing electrode fault. Medium Engineer View Guide
F.88 Unstable Flame / Gas Valve Fault (Energy Range) On Glow-worm Energy boilers, F.88 indicates an unstable flame signal — possible underfloor heating contact issue… High Engineer View Guide
F.89 Pump Fault (Energy Range) On Glow-worm Energy boilers, F.89 indicates a pump fault. High Engineer View Guide
F00 Flow Temperature Sensor Fault (Betacom/Ultracom) On Glow-worm Betacom and Ultracom models, F00 (or F10, F71) indicates a flow heating temperature sensor… Medium Engineer View Guide
F01 Return Temperature Sensor Fault (Betacom/Ultracom) On Glow-worm Betacom and Ultracom models, F01 (or F11) indicates a return heating temperature sensor fault. Medium Engineer View Guide
F1 Ignition Failure / Lockout The boiler has failed to ignite after five attempts and entered lockout. In winter, the most… Medium DIY View Guide
F10 CH Return Thermistor Fault (Older Ranges) On older Glow-worm ranges, F10 indicates a central heating return thermistor fault. Medium Engineer View Guide
F11 Flow/Return Temperature Sensor Fault A temperature sensor (NTC thermistor) on either the flow or return pipework has failed or has… Medium Engineer View Guide
F12 PCB Fault / Communication Error The PCB has detected an internal fault or a communication error with a connected controller. High Engineer View Guide
F13 DHW Temperature Sensor Fault The domestic hot water temperature sensor has failed or has a wiring issue. On combi boiler… Medium Engineer View Guide
F14 Gas Valve Control Defective (Older Ranges) On Glow-worm Flexicom and Ultracom models, F14 indicates the gas valve control is defective. High Engineer View Guide
F15 eBUS Voltage Fault (Older Ranges) On Glow-worm Flexicom and Ultracom models, F15 indicates an eBUS voltage failure. Medium Engineer View Guide
F16 Fan / Wiring Fault The fan has a fault in its motor or wiring. Different from F32 which is a… High Engineer View Guide
F17 Gas Valve Closing Fault The gas valve is not closing properly after the burner shuts down. High Engineer View Guide
F18 Low Water Pressure System water pressure has dropped below the safe minimum. Low DIY View Guide
F19 Flow/Return Differential Too High The temperature gap between flow and return is too large, indicating poor circulation. Medium Engineer View Guide
F2 Flame Supervision Fault The flame supervision device has detected an issue with the flame signal. High Engineer View Guide
F20 Safety Overheat Lockout The safety thermostat has triggered due to overheating. Identical to Vaillant F.20 as Glow-worm uses the… High Engineer View Guide
F21 Flow Rate Sensor Fault The water flow rate sensor is giving incorrect readings. Medium Engineer View Guide
F22 Low Water Pressure The system water pressure has dropped below the minimum required level. This is the modern equivalent… Low DIY View Guide
F23 Temperature Spread Too High The difference between flow and return temperatures is too great, indicating poor circulation. Medium Engineer View Guide
F24 Rapid Temperature Rise The flow temperature is rising faster than 10°C per second, indicating a circulation problem. High Engineer View Guide
F25 Circulation Fault (All Ranges) On all Glow-worm boiler ranges, F25 (or F23) indicates a circulation fault — insufficient water flow… Medium Engineer View Guide
F26 Gas Valve Stepper Motor Fault The gas valve stepper motor is not responding correctly. High Engineer View Guide
F27 Ionisation Fault Despite Gas Valve Off A flame signal is detected even though the gas valve should be closed. High Engineer View Guide
F28 Ignition Failure (Modern Models) On newer Glow-worm Energy and Ultimate models, F28 indicates the boiler has failed to detect a… Medium DIY View Guide
F29 Flame Loss During Operation The boiler ignited but then lost the flame during operation. Medium DIY View Guide
F3 Flue Gas Sensor Fault The flue gas temperature sensor is reading outside normal range. High Engineer View Guide
F30 Outdoor Sensor Fault The outdoor temperature sensor is disconnected or faulty. Low Engineer View Guide
F31 Outdoor Sensor Short Circuit The outdoor NTC sensor wiring has a short circuit. Low Engineer View Guide
F32 Fan Error The boiler fan is not running at the required speed. Shared with Vaillant as part of… High Engineer View Guide
F33 Flue Gas Recirculation Flue gases are being drawn back into the air intake, affecting combustion. High Engineer View Guide
F34 Mains Voltage Fault The mains supply voltage is outside the acceptable range. Medium Engineer View Guide
F35 Mains Frequency Fault The mains supply frequency is outside the acceptable 50Hz range. Medium Engineer View Guide
F36 eBUS Communication Fault The communication bus between boiler components has failed. High Engineer View Guide
F37 Fan Speed Too Low The fan is running below the minimum required speed. High Engineer View Guide
F38 Fan Speed Too High The fan is running faster than expected. Medium Engineer View Guide
F39 Outdoor Temp Sensor — Freeze Warning The outdoor sensor has detected a temperature near freezing. Frost protection may be active. Medium DIY View Guide
F4 Gas Supply / Ignition Lockout The boiler has failed to ignite after five attempts — typically indicating a gas supply issue… Medium DIY View Guide
F41 DHW Sensor Open Circuit The domestic hot water NTC sensor has an open circuit. Medium Engineer View Guide
F42 Coding Plug Fault The boiler coding plug is missing or cannot be read. High Engineer View Guide
F43 Generic Internal Error (Flexicom/Ultracom) On Glow-worm Flexicom and Ultracom models, F43 indicates a generic internal fault code. High Engineer View Guide
F44 Diverter Valve Fault The diverter valve is stuck or not switching correctly. Medium Engineer View Guide
F45 DHW Sensor Short Circuit The DHW NTC sensor wiring has a short circuit. Medium Engineer View Guide
F46 Low Gas Pressure Detected The boiler is detecting that the gas supply pressure is too low. High Engineer View Guide
F47 Mixed Gas Pressure Fault Both low gas pressure and flame supervision faults are occurring. High Engineer View Guide
F48 Phase/Neutral Reversed The mains electricity supply has reversed live and neutral connections. High Engineer View Guide
F49 eBUS Communication Fault Communication failure between the boiler and a connected Vaillant Group controller (sensoCOMFORT, sensoHOME, MiGo etc.) over… Medium Engineer View Guide
F5 Overheat Fault The boiler has detected an overtemperature condition and shut down for safety. On older Glow-worm Betacom… High Engineer View Guide
F50 DHW Thermistor Open Circuit The hot water thermistor circuit is broken. Medium Engineer View Guide
F51 Flow Thermistor Drift The flow sensor readings are drifting outside expected values. Medium Engineer View Guide
F52 Cylinder Sensor Fault The hot water cylinder NTC sensor has a fault (system boilers). Medium Engineer View Guide
F53 Return Thermistor Drift The return sensor readings are drifting. Medium Engineer View Guide
F54 Gas Pressure Too Low The gas supply pressure to the boiler is below the minimum required. High Engineer View Guide
F55 CO Sensor Fault The carbon monoxide safety sensor is not reading correctly. High Engineer View Guide
F56 EEPROM Error The electronic memory on the PCB has developed an error. High Engineer View Guide
F57 eBUS Short Circuit The eBUS communication line has a short circuit. Medium Engineer View Guide
F58 Pump Kickback Fault The pump restart sequence has failed. Medium Engineer View Guide
F59 Comfort Mode Fault A fault has occurred in the comfort/pre-heat operating mode. Medium Engineer View Guide
F6 CH Flow Thermistor Fault (Older Ranges) On older Glow-worm ranges, F6 indicates a central heating flow thermistor fault. Medium Engineer View Guide
F60 Gas Valve Driver Fault The PCB is unable to drive the gas valve correctly. High Engineer View Guide
F61 Gas Valve Regulation Error The gas valve has an electronic fault. Shared fault code across the Vaillant Group. High Engineer View Guide
F62 Gas Valve Timing Fault The gas valve is not opening/closing with the correct timing. High Engineer View Guide
F63 EEPROM Fault Memory fault on the main PCB. The boiler cannot read its stored configuration data. High Engineer View Guide
F64 NTC Sensor Short Circuit / PCB Fault A short circuit involving an NTC temperature sensor or an internal PCB fault. Shared across Vaillant… High Engineer View Guide
F65 Electronics Temperature Too High The temperature of the PCB electronics itself has exceeded safe operating limits. May indicate an external… High Engineer View Guide
F66 Frost Protection Active The boiler is running in frost protection mode to prevent freezing. Medium DIY View Guide
F67 PCB Electronics Temperature The PCB electronics are running too hot. Medium Engineer View Guide
F68 Flame Instability The flame signal is fluctuating, indicating unstable combustion. High Engineer View Guide
F69 CO Sensor — High Reading The CO sensor has detected elevated carbon monoxide levels in combustion. High Engineer View Guide
F7 DHW Thermistor Fault (Older Ranges) On older Glow-worm ranges, F7 indicates a domestic hot water thermistor fault. Medium Engineer View Guide
F70 Invalid Device Specific Number (DSN) The boiler has an invalid or unrecognised device-specific configuration number. Usually occurs after PCB replacement. Medium Engineer View Guide
F71 Flow Sensor Constant Value The flow sensor is returning the same reading regardless of temperature changes. Medium Engineer View Guide
F72 Flow/Return Delta Too Large The temperature difference between flow and return is abnormally large. Medium Engineer View Guide
F73 Water Pressure Sensor Signal Too Low The pressure sensor is reading below its expected range. Could mean genuinely very low pressure or… High Engineer View Guide
F74 Water Pressure Sensor Signal Too High The pressure sensor is reading above its expected operating range, indicating a faulty sensor or very… High Engineer View Guide
F75 Pump / Pressure Sensor Fault The boiler cannot detect a pressure change when the pump starts. Because Glow-worm is part of… Medium DIY View Guide
F76 Thermal Fuse Fault (Betacom/Ultracom) On Glow-worm Betacom and Ultracom models, F76 indicates a thermal fuse fault. The thermal fuse is… High Engineer View Guide
F77 Condensate System Fault / Pump Fault A fault with the condensate system or pump. On models with a condensate pump, this may… Medium Engineer View Guide
F78 DHW Outlet Sensor Not Bridged The hot water NTC is not connected or bridged (when an external controller is fitted). Medium Engineer View Guide
F8 Return NTC Sensor Short Circuit The return water NTC sensor has a short circuit. Medium Engineer View Guide
F80 Condensate Drain Fault The condensate cannot drain freely, possibly due to a blockage or freeze. Medium DIY View Guide
F81 Pump Stuck The circulation pump has seized and is unable to rotate. High Engineer View Guide
F82 Pressure Sensor Fault The electronic water pressure sensor is reading incorrectly. Medium Engineer View Guide
F84 Flow / Return Sensors Transposed The flow and return temperature sensors appear to be reading inverted values. Usually a post-service issue. High Engineer View Guide
F85 Flow/Return Sensors Same Pipe Both temperature sensors are fitted to the same pipe. Medium Engineer View Guide
F86 Underfloor Heating Contact Fault On Glow-worm boilers connected to underfloor heating systems, F86 indicates a fault with the underfloor heating… Medium Engineer View Guide
F9 Pressure Sensor / Low Pressure The boiler pressure sensor is detecting an issue — either the system pressure is too low,… Medium DIY View Guide
F90 Coding Resistor Mismatch The coding resistor does not match the gas type setting. High Engineer View Guide
F91 Cylinder Sensor Short Circuit The hot water cylinder sensor has a short circuit. Medium Engineer View Guide
F92 Gas Type Mismatch The boiler configuration does not match the connected gas supply. High Engineer View Guide
F93 Combustion Quality Fault Combustion quality is outside the permitted range. High Engineer View Guide