F75 FAULT CODE
Glow-worm

Pump / Pressure Sensor Fault

Medium Severity DIY Check Possible

The boiler cannot detect a pressure change when the pump starts. Because Glow-worm is part of the Vaillant Group, this fault is identical to Vaillant F.75 — the most common fault across both brands.

Step-by-Step Fix Guide

  1. Step 1

    Check the system pressure gauge — it should read 1.0–1.5 bar

  2. Step 2

    Repressurise using the filling loop if below 1 bar

  3. Step 3

    Bleed all radiators to remove airlocks

  4. Step 4

    Reset the boiler

  5. Step 5

    If the fault returns, the pump or pressure sensor may need replacing — call a Gas Safe engineer

Gas Safe Reminder

Work on gas appliances must be carried out by a Gas Safe registered engineer. The steps above cover safe checks a homeowner can perform - any internal component replacement requires a qualified professional. If in doubt, always call an engineer.