HE 120T Fault Codes 31

Code Description Severity Type
01 Ignition Failure (CSI) On Ravenheat CSI boilers, code 01 indicates the boiler has failed to ignite — check gas… Medium DIY View Guide
04 Overheat Thermostat Fault (CSI) On Ravenheat CSI boilers, code 04 indicates the overheat thermostat needs checking. High Engineer View Guide
28 Low Water Pressure / Pump Fault (CSI) On Ravenheat CSI 120 boilers, code 28 indicates a failed low water pressure switch or pump… Low DIY View Guide
E01 Ignition Failure Failed to ignite. High Engineer View Guide
E02 Pump Circulation Problem On Ravenheat CS/WH/HE models, E02 indicates a problem with the pump circulation — the pump may… Medium Engineer View Guide
E03 Flow Sensor Damaged The flow temperature sensor has failed or has a wiring fault. Medium Engineer View Guide
E04 DHW Sensor Damaged On CS/WH/HE models, E04 indicates the domestic hot water sensor has failed. Medium Engineer View Guide
E05 Fan Fault — No Signal The fan is not running or there is no fan speed signal. The fan may be… High Engineer View Guide
E06 CH Sensor Overheating The central heating temperature sensor is detecting an overtemperature condition. High Engineer View Guide
E07 Overheat Protection Safety thermostat activated. High Engineer View Guide
E08 Low Water Pressure System water pressure is below the safe minimum on Ravenheat CS/WH/HE boilers. Low DIY View Guide
E09 Overheat Sensor Overheating The overheat thermostat sensor has detected a dangerous temperature. High Engineer View Guide
E10 High Water Pressure The system water pressure is too high on Ravenheat boilers. Medium Engineer View Guide
E11 PCB Fault Internal PCB error. High Engineer View Guide
E12 Return NTC Fault Return sensor faulty. Medium Engineer View Guide
E13 DHW NTC Fault Hot water sensor faulty. Medium Engineer View Guide
E14 Pump Fault Pump not running. High Engineer View Guide
E15 Fan Fault Fan not running correctly. High Engineer View Guide
E16 Air Pressure Switch APS fault. High Engineer View Guide
E17 Low Water Pressure Pressure too low. Low DIY View Guide
E18 Gas Valve Fault Gas valve not responding. High Engineer View Guide
E19 Condensate Blocked Condensate pipe blocked. Medium DIY View Guide
E20 Diverter Valve Fault Valve stuck. Medium Engineer View Guide
E21 Flame Lost Flame lost during operation. High Engineer View Guide
E22 Flue Sensor Overheating The flue gas sensor has detected an overtemperature condition in the flue. High Engineer View Guide
E23 Flue Sensor Damaged The flue temperature sensor has failed or has a wiring fault. Medium Engineer View Guide
E24 Combustion Fault Air/gas mixture outside limits. High Engineer View Guide
E25 Heat Exchanger Frozen The main heat exchanger has frozen. This typically occurs when the boiler is in an unheated… High DIY View Guide
E26 Rapid Temperature Rise Flow temp rising too fast. High Engineer View Guide
E27 Pressure Sensor Fault Electronic sensor faulty. Medium Engineer View Guide
E46 Water Pressure Sensor Error The water pressure sensor circuit is either open or short-circuited. Medium Engineer View Guide