Navien
NCB 700 System 24
System Boiler
24kW
2021-present
ErP A
43 fault codes
<p>The NCB 700 System 24 is a system boiler from Navien, available at 24kW output. Produced 2021-present.</p>
NCB 700 System 24 Fault Codes 43
Code
Description
Severity
Type
001
Ignition Failure
The boiler has failed to ignite after multiple attempts. The gas supply, spark electrodes, or gas…
High
Engineer
View Guide
002
Flame Loss During Operation
The flame was established but has been lost unexpectedly. This may indicate a gas supply interruption.
High
Engineer
View Guide
003
Ignition Failure
The boiler has failed to ignite — manual reset required. The most common Navien fault code.…
Medium
DIY
View Guide
004
False Flame (Auto-Reset)
The boiler has detected a flame signal when not expected. This version auto-resets but if it…
Medium
DIY
View Guide
010
Abnormal Exhaust Temperature
The exhaust gas temperature is outside the normal range. The boiler has shut down as a…
High
Engineer
View Guide
011
Abnormal Air Pressure
The air pressure switch is not detecting correct air flow through the combustion chamber.
High
Engineer
View Guide
012
Flame Loss During Operation
The boiler ignited but then lost its flame during operation. Reset required.
Medium
DIY
View Guide
015
PCB Fault
The main printed circuit board has an internal error or communication fault.
High
Engineer
View Guide
016
Heat Exchanger Overheated
The primary heat exchanger has detected an overtemperature condition. Manual reset required.
High
Engineer
View Guide
027
Low Water Flow
The water flow rate through the boiler is too low for safe operation.
Medium
Engineer
View Guide
030
Abnormal Exhaust Temperature
The exhaust (flue gas) temperature is abnormal — either too high or there is a flue…
High
Engineer
View Guide
032
DHW Thermistor Fault
The domestic hot water temperature sensor has developed a fault.
Medium
Engineer
View Guide
036
Heating Thermistor Fault
The central heating temperature sensor has developed a fault.
Medium
Engineer
View Guide
046
Heat Exchanger Overheating (Auto-Reset)
Abnormal heat exchanger overheating — the boiler should auto-reset. If recurring, investigate circulation.
Medium
Engineer
View Guide
109
Fan Error
The boiler fan is not operating correctly. The boiler needs resetting after checking the fan.
High
Engineer
View Guide
110
Exhaust Blockage / Condensate Blockage
The exhaust system or condensate drain is blocked. On Navien boilers this is the specific code…
Medium
DIY
View Guide
127
Air Pressure Switch (APS) Issue
The air pressure switch is not operating correctly — it is not confirming adequate airflow before…
High
Engineer
View Guide
205
Heating Supply Thermistor Fault
The heating supply (flow) thermistor has an open or short circuit fault. The boiler may auto-reset.
Medium
Engineer
View Guide
218
Heating Return Thermistor Fault
The heating return thermistor has an open or short circuit fault.
Medium
Engineer
View Guide
302
Low Water Pressure
The system water pressure has dropped below the safe minimum. The boiler should auto-reset once pressure…
Low
DIY
View Guide
352
High Water Pressure
The system water pressure is too high. The boiler should auto-reset once pressure drops.
Medium
Engineer
View Guide
407
Room Controller Communication Error
The boiler has lost communication with the room controller or thermostat.
Low
DIY
View Guide
594
EEPROM Error (PCB)
There is a memory fault on the main PCB. Contact an engineer — this cannot be…
High
Engineer
View Guide