Skip to main content

Navien

NCB 700 28

Combi Boiler 28kW 2021-present ErP A 43 fault codes

<p>The NCB 700 28 is a combi boiler from Navien, available at 28kW output. Produced 2021-present.</p>

NCB 700 28 Fault Codes 43

Code Description Severity Type
001 Ignition Failure The boiler has failed to ignite after multiple attempts. The gas supply, spark electrodes, or gas… High Engineer View Guide
002 Flame Loss During Operation The flame was established but has been lost unexpectedly. This may indicate a gas supply interruption. High Engineer View Guide
003 Ignition Failure The boiler has failed to ignite — manual reset required. The most common Navien fault code.… Medium DIY View Guide
004 False Flame (Auto-Reset) The boiler has detected a flame signal when not expected. This version auto-resets but if it… Medium DIY View Guide
005 Abnormal Ignition Ignition occurring outside expected parameters. High Engineer View Guide
006 False Flame Signal Flame detected when gas valve should be closed. High Engineer View Guide
007 Fan Fault Fan not operating within expected speed range. High Engineer View Guide
008 Exhaust Blockage The flue is blocked or partially obstructed. High Engineer View Guide
009 Air Pressure Switch Fault APS not detecting correct airflow. High Engineer View Guide
010 Abnormal Exhaust Temperature The exhaust gas temperature is outside the normal range. The boiler has shut down as a… High Engineer View Guide
011 Abnormal Air Pressure The air pressure switch is not detecting correct air flow through the combustion chamber. High Engineer View Guide
012 Flame Loss During Operation The boiler ignited but then lost its flame during operation. Reset required. Medium DIY View Guide
013 Low Water Pressure System pressure below minimum. Low DIY View Guide
014 Pump Fault Pump not running or seized. High Engineer View Guide
015 PCB Fault The main printed circuit board has an internal error or communication fault. High Engineer View Guide
016 Heat Exchanger Overheated The primary heat exchanger has detected an overtemperature condition. Manual reset required. High Engineer View Guide
017 PCB Fault Internal PCB communication error. High Engineer View Guide
018 Overheat Protection Safety thermostat activated. High Engineer View Guide
019 Condensate Blocked Condensate drain blocked or frozen. Medium DIY View Guide
020 DHW Overheat Hot water temperature exceeded safe limit. High Engineer View Guide
027 Low Water Flow The water flow rate through the boiler is too low for safe operation. Medium Engineer View Guide
028 Diverter Valve Fault Valve stuck or not switching. Medium Engineer View Guide
030 Abnormal Exhaust Temperature The exhaust (flue gas) temperature is abnormal — either too high or there is a flue… High Engineer View Guide
031 Flow Sensor Short Circuit Flow NTC wiring has a short. Medium Engineer View Guide
032 DHW Thermistor Fault The domestic hot water temperature sensor has developed a fault. Medium Engineer View Guide
033 Gas Valve Fault Gas valve not responding. High Engineer View Guide
034 Return Sensor Fault Return NTC has a fault. Medium Engineer View Guide
035 Flow Sensor Open Circuit Flow NTC circuit broken. Medium Engineer View Guide
036 Heating Thermistor Fault The central heating temperature sensor has developed a fault. Medium Engineer View Guide
038 Combustion Fault Air/gas mixture outside limits. High Engineer View Guide
040 eBUS Fault Communication fault. Medium Engineer View Guide
041 Frost Protection Active Frost protection running. Medium DIY View Guide
042 Pressure Sensor Fault Electronic sensor faulty. Medium Engineer View Guide
046 Heat Exchanger Overheating (Auto-Reset) Abnormal heat exchanger overheating — the boiler should auto-reset. If recurring, investigate circulation. Medium Engineer View Guide
109 Fan Error The boiler fan is not operating correctly. The boiler needs resetting after checking the fan. High Engineer View Guide
110 Exhaust Blockage / Condensate Blockage The exhaust system or condensate drain is blocked. On Navien boilers this is the specific code… Medium DIY View Guide
127 Air Pressure Switch (APS) Issue The air pressure switch is not operating correctly — it is not confirming adequate airflow before… High Engineer View Guide
205 Heating Supply Thermistor Fault The heating supply (flow) thermistor has an open or short circuit fault. The boiler may auto-reset. Medium Engineer View Guide
218 Heating Return Thermistor Fault The heating return thermistor has an open or short circuit fault. Medium Engineer View Guide
302 Low Water Pressure The system water pressure has dropped below the safe minimum. The boiler should auto-reset once pressure… Low DIY View Guide
352 High Water Pressure The system water pressure is too high. The boiler should auto-reset once pressure drops. Medium Engineer View Guide
407 Room Controller Communication Error The boiler has lost communication with the room controller or thermostat. Low DIY View Guide
594 EEPROM Error (PCB) There is a memory fault on the main PCB. Contact an engineer — this cannot be… High Engineer View Guide

Are you a Gas Safe Engineer?

Access technical fault data, wiring diagrams, and parts lists. Free for verified Gas Safe engineers.