Skip to main content

Main Heating

Combi 25 HE A

Combi Boiler 25kW 2010-2016 ErP B 41 fault codes

<p>The Combi 25 HE A is a combi boiler from Main Heating, available at 25kW output. Produced 2010-2016.</p>

Combi 25 HE A Fault Codes 41

Code Description Severity Type
E09 Gas Valve Connection Error On Main Eco Compact boilers, code E09 indicates a fault in the gas valve connection cable. High Engineer View Guide
E10 DHW NTC Fault Hot water sensor faulty. Medium Engineer View Guide
E109 Pre-Circulation Fault The boiler has detected insufficient circulation during its pre-circulation check. Medium Engineer View Guide
E11 Return NTC Fault Return sensor faulty. Medium Engineer View Guide
E110 Overheat Lockout The boiler has overheated and the safety thermostat has triggered. High Engineer View Guide
E119 Low Water Pressure System pressure has dropped below 0.5 bar. Main Heating boilers share the same fault code system… Low DIY View Guide
E12 Flow NTC Short Circuit Flow sensor shorted. Medium Engineer View Guide
E125 Primary Circuit Circulation Fault Insufficient water circulation through the primary heating circuit. Medium Engineer View Guide
E128 Loss of Flame During Operation The boiler has lost its flame 12 times during operation, triggering a safety lockout. High Engineer View Guide
E13 Return NTC Short Circuit Return sensor shorted. Medium Engineer View Guide
E130 Flue Thermostat Tripped The flue safety thermostat has activated due to excessively high flue temperatures. High Engineer View Guide
E133 Ignition Failure / Frozen Condensate The boiler has failed to ignite. Identical to Baxi E133 — Main Heating shares the BDR… Medium DIY View Guide
E135 Gas Supply Interruption The gas supply to the boiler has been interrupted. Medium DIY View Guide
E14 DHW NTC Short Circuit DHW sensor shorted. Medium Engineer View Guide
E15 Diverter Valve Fault Valve stuck or not switching. Medium Engineer View Guide
E154 Flow/Return Sensor Test Failure The boiler's internal sensor cross-check test has failed. Medium Engineer View Guide
E16 Condensate Blocked Condensate pipe blocked. Medium DIY View Guide
E160 Fan Fault The boiler fan has a fault — not running, running slowly, or speed sensor failure. High Engineer View Guide
E168 PCB Lockout / Unspecified Fault The PCB has detected an unspecified fault and locked out the boiler. High Engineer View Guide
E17 Fan Fault Fan not running correctly. High Engineer View Guide
E18 Gas Valve Fault Gas valve not responding. High Engineer View Guide
E19 Pump Fault Pump not running. High Engineer View Guide
E20 CH NTC Sensor Fault Central heating thermistor sensor fault on Main Heating boilers. Medium Engineer View Guide
E21 PCB Fault Internal PCB error. High Engineer View Guide
E22 Low Gas Pressure Gas pressure too low. High Engineer View Guide
E23 Air Pressure Switch APS fault. High Engineer View Guide
E24 Flame Instability Flame signal fluctuating. High Engineer View Guide
E25 Overheat Protection Safety thermostat activated. High Engineer View Guide
E26 Rapid Temperature Rise Flow temp rising too fast. High Engineer View Guide
E27 Pressure Sensor Fault Electronic sensor faulty. Medium Engineer View Guide
E270 Dry Fire Detected The boiler has fired without adequate water circulation — a dry fire condition. High Engineer View Guide
E28 Frozen Condensate / Flue Thermistor Fault In cold weather, E28 on Main Heating boilers indicates a frozen condensate pipe. In warmer conditions,… Medium DIY View Guide
E30 Frost Protection Active Frost protection running. Medium DIY View Guide
E31 eBUS Fault Communication fault. Medium Engineer View Guide
E32 Combustion Fault Air/gas mixture outside limits. High Engineer View Guide
E321 Hot Water NTC Fault (Eco Compact) On Main Eco Compact boilers, E321 indicates a hot water thermistor fault. Medium Engineer View Guide
E384 False Flame Detected The boiler is detecting a flame signal when the gas valve should be closed. High Engineer View Guide
E40 CH Return Sensor Error Central heating return sensor has a fault on Main Eco Compact boilers. Medium Engineer View Guide
E50 Hot Water NTC Fault The domestic hot water temperature sensor has a fault on Main Heating boilers. Medium Engineer View Guide
E60 Fan or Fan Wiring Fault On some older Main boilers, E60 indicates a fan or fan wiring fault. High Engineer View Guide
E83 Communication Error A communication error between the boiler PCB and external controls or room controller. Medium Engineer View Guide

Are you a Gas Safe Engineer?

Access technical fault data, wiring diagrams, and parts lists. Free for verified Gas Safe engineers.