Advance 30kW

System Boiler 30kW 2015-present ErP A 40 fault codes

<p>The Advance 30kW is a system boiler from Heatline, available at 30kW output. Produced 2015-present.</p>

Advance 30kW Fault Codes 40

Code Description Severity Type
F00 Flow Temperature Sensor Fault The heating flow temperature sensor (F00) or return sensor (F01) has a wiring or sensor fault. Medium Engineer View Guide
F01 Flow NTC Fault Flow sensor has a fault. Medium Engineer View Guide
F02 Return NTC Fault Return sensor has a fault. Medium Engineer View Guide
F03 Overheat Safety thermostat activated. High Engineer View Guide
F04 Gas Valve Fault Gas valve not responding. High Engineer View Guide
F05 Fan Fault Fan not operating correctly. High Engineer View Guide
F06 Air Pressure Switch APS not detecting airflow. High Engineer View Guide
F07 PCB Fault Internal PCB error. High Engineer View Guide
F08 Low Water Pressure Pressure too low. Low DIY View Guide
F09 Pump Fault Pump not running. High Engineer View Guide
F10 DHW NTC Fault Hot water sensor faulty. Medium Engineer View Guide
F11 Condensate Blocked Condensate pipe blocked. Medium DIY View Guide
F12 Diverter Valve Fault Valve stuck. Medium Engineer View Guide
F13 Ignition Failure Failed to ignite. High Engineer View Guide
F14 Flame Lost Flame lost during operation. High Engineer View Guide
F15 Combustion Fault Air/gas mixture outside limits. High Engineer View Guide
F16 Pressure Sensor Fault Electronic sensor faulty. Medium Engineer View Guide
F17 Flame Detected After Shutdown Flame signal with gas off. High Engineer View Guide
F18 External Thermostat Fault Thermostat signal incorrect. Medium Engineer View Guide
F19 Rapid Temperature Rise Flow temp rising too fast. High Engineer View Guide
F20 Overheat Fault The boiler has overheated and the safety limiter has activated. Caused by poor circulation, low water… High Engineer View Guide
F21 Flow/Return Reversed Sensors on wrong pipes. Medium Engineer View Guide
F22 Low Water Pressure System water pressure has dropped below the safe minimum for the boiler to operate. Low DIY View Guide
F23 Flow/Return Temperature Difference Too High The temperature difference between flow and return is excessive, indicating circulation problems. Medium Engineer View Guide
F24 Water Circulation Fault The boiler has detected insufficient water circulation. Isolation valves may be closed or the pump may… Medium Engineer View Guide
F25 Outdoor Sensor Fault Outdoor sensor faulty. Low Engineer View Guide
F26 Gas Valve Motor Fault The gas valve motor has a fault, or the condensate pump is not operating correctly. High Engineer View Guide
F27 Flame Detection Fault The flame detection electrode has a fault. The boiler may ignite but cannot confirm the flame… High Engineer View Guide
F28 Ignition Failure The most common Heatline fault code. The boiler has failed to ignite. Very commonly caused by… Medium DIY View Guide
F29 Flame Loss During Operation The boiler ignited but then lost its flame during operation. Often caused by gas supply issues… Medium DIY View Guide
F30 eBUS Fault Communication fault. Medium Engineer View Guide
F31 EEPROM Error PCB memory error. High Engineer View Guide
F32 Incorrect Air Pressure / Flue Fault The air pressure switch is not confirming correct airflow. May indicate a blocked flue, fan fault,… High Engineer View Guide
F33 Mains Voltage Fault Voltage outside range. Medium Engineer View Guide
F35 Frost Protection Frost protection active. Medium DIY View Guide
F49 eBUS Communication Fault There is a communication fault on the eBUS — the communication bus between the boiler and… Medium Engineer View Guide
F72 Flow/Return Sensor Temperature Drift A permanent temperature difference has been detected between the flow and return sensors, indicating a sensor… Medium Engineer View Guide
F73 Heating Circuit Pressure Sensor Fault The heating circuit water pressure sensor has a fault. Medium Engineer View Guide
F76 Thermal Fuse Fault The thermal fuse on the heat exchanger has blown due to extreme overheating. The heat exchanger… High Engineer View Guide
F83 No Water Detected / Dry Fire The boiler has fired but no temperature rise was detected, indicating the system has no water… High Engineer View Guide