S.41 FAULT CODE
Vaillant

System Pressure Too High (>2.8 bar)

Medium Severity Engineer Required

Status code: The system water pressure has exceeded 2.8 bar. The boiler is blocking for safety. This can be caused by the filling loop being left open or a faulty pressure relief valve.

Step-by-Step Fix Guide

  1. Step 1

    Do NOT add more water to the system

  2. Step 2

    Check that the filling loop is fully closed

  3. Step 3 Engineer only

    If pressure remains above 2.8 bar, call a Gas Safe engineer — the pressure relief valve may need to be operated or the expansion vessel may have failed

Gas Safe Reminder

Work on gas appliances must be carried out by a Gas Safe registered engineer. The steps above cover safe checks a homeowner can perform - any internal component replacement requires a qualified professional. If in doubt, always call an engineer.