F.75 FAULT CODE
Vaillant

Pump / Pressure Sensor Fault

Medium Severity DIY Check Possible

The boiler cannot detect a pressure change when the pump starts. This is the most common Vaillant fault code, typically indicating a faulty pump, airlocked system, or failed pressure sensor.

Step-by-Step Fix Guide

  1. Step 1

    Check the system pressure gauge — it should read 1.0 to 1.5 bar

  2. Step 2

    If low, repressurise using the filling loop

  3. Step 3

    Bleed all radiators to remove airlocks, starting from the ground floor

  4. Step 4

    Reset the boiler

  5. Step 5

    Listen for the pump running (a quiet hum from inside the boiler casing)

  6. Step 6

    If pressure is correct and pump sounds normal but fault returns, the pressure sensor needs replacing — call a Gas Safe engineer

Gas Safe Reminder

Work on gas appliances must be carried out by a Gas Safe registered engineer. The steps above cover safe checks a homeowner can perform - any internal component replacement requires a qualified professional. If in doubt, always call an engineer.