E16 FAULT CODE
Biasi

Condensate Trap Full / Blocked

Medium Severity DIY Check Possible

The condensate trap is full or the drain pipe is blocked. Condensate cannot drain freely.

Cold Weather Note

Frozen condensate pipes are very common in cold weather. Insulating the pipe can prevent this.

Step-by-Step Fix Guide

  1. Step 1

    Check the external condensate pipe for blockages or ice

  2. Step 2

    Pour warm (not boiling) water over any frozen sections

  3. Step 3

    Clear any debris from the drain exit

  4. Step 4

    Reset the boiler after clearing

Gas Safe Reminder

Work on gas appliances must be carried out by a Gas Safe registered engineer. The steps above cover safe checks a homeowner can perform - any internal component replacement requires a qualified professional. If in doubt, always call an engineer.